background image

10-3. Square Embedded Type Pressure Gauge Replacement

Applicable

model

Work

category

Tool

Criteria

1)

Remove the pressure gauge cover.
Rotate the pressure gauge cover 15 degrees in
the arrow direction (counterclockwise) and pull
it out.

-

2)

Remove the pressure gauge.
Remove the 2 mounting screws and remove
the pressure gauge.

Phillips

screwdriver

3)

Confirm that the O-ring is mounted onto the
pressure gauge.
When the O-ring comes out or is left on the
regulator, mount the O-ring to the pressure
gauge correctly.

-

Presence of the O-ring

4)

Mount the pressure gauge.
Mount the pressure gauge to the regulator with
the mounting screws and tighten the screws
referring to the tightening torque specified in the
right column.

Phillips

screwdriver

Tightening torque:

0.85+/-0.05 N m

5)

Mount the pressure gauge cover.
Set the pressure gauge cover with its arrow on
the lower right corner. Mate the 2 fingers of the
pressure gauge cover with the 2 finger slits of
the pressure gauge, and rotate the pressure
gauge cover 15 degrees to the opposite
direction of the arrow (clockwise).

-

Note) Applicable to the product with square embedded type pressure gauge (E).

-18-

Procedure

AR20
AR20K
AR30
AR30K
AR40
AR40K
AR50
AR50K
AR60
AR60K

Assembly

Disassembly

(5)

Pressure gauge cover assembly

Mounting screws
(2 pcs.)

Pressure gauge

O-ring

(5)

Pressure gauge cover

(4)

Square embedded type pressure gauge

Содержание AR20 Series

Страница 1: ...2 E3 E4 G H M 1 N R Y Z ZA D AR30 K F N 02 F N 03 B E E1 E2 E3 E4 G H M 1 N R Y Z ZA D AR40 K F N 02 F N 04 B E E1 E2 E3 E4 G H M 1 N R Y Z ZA D AR40 K F N 06 B E E1 E2 E3 E4 G H M 1 N R Y Z ZA D AR50...

Страница 2: ...oting 14 15 10 How to Replace the Components 16 22 10 1 Diaphragm Assembly Replacement 16 10 2 Valve Guide Assembly and Valve Assembly Replacement 17 10 3 Square Embedded Type Pressure Gauge Replaceme...

Страница 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Страница 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Страница 5: ...tion to release the residual pressure completely 3 Long absence of operation or operation with sealed circuit or balancing circuit on the outlet side may cause set pressure fluctuation Please consult...

Страница 6: ...difference between the inlet and the outlet Please consult SMC it chattering continues Piping Warning 1 Before piping is connected it should be thoroughly blown out with air flushing or washed to remo...

Страница 7: ...e procedure in this operation manual Incorrect handling of the product may cause breakage or operation failure of the equipment or device 3 When using the regulator with backflow function between a so...

Страница 8: ...d fluid temperature Note 2 Proof pressure Max operating pressure Set pressure range Construction Weight 0 14kg 0 27kg 0 48kg 0 51kg 1 13kg 1 25kg Note 2 5 to 50o C for the products with the digital pr...

Страница 9: ...output Wiring bottom entry E4 PNP output Wiring top entry Nil 0 05 to 0 85 MPa setting 1 0 02 to 0 2 MPa setting Nil Relieving type N Non relieving type Nil Flow direction Left to right R Flow direct...

Страница 10: ...mounting G36 10 01 L ZA Unit selection function Unit selection function Initial setting psi 4 3 NPT With O ring 1 pc and mounting screws 2 pcs Part number for 0 2 MPa GC3 4AS D Rc NPT type GC3 P4AS D...

Страница 11: ...AS AR54P 060AS AR64P 060AS Relief AR24P 150AS AR34P 150AS N Non relief AR24P 150AS N AR34P 150AS N 9 Valve guide assembly AR24P 050AS AR34P 050AS Rc G NPT 11 Blanking plate assembly Rc NPT G 13 Check...

Страница 12: ...y with the bracket The knurling of the bracket and set nut stops loosening of the screw Usually these can be tightened adequately by hand Extra tightening is recommended for panel mounting Fix the bra...

Страница 13: ...uge Please refer to Piping on page 5 when using sealing tape Please use the value in the torque table described in Piping on page 5 when controlling the tightening torque No plug is mounted onto the p...

Страница 14: ...ockwise pressure decreases Note Adjust the pressure in pressure increasing direction rotate in the arrow direction Otherwise it may cause insufficient set pressure 3 After adjusting pressure lock the...

Страница 15: ...ve assembly P17 2 Rubber seat of the valve is damaged Replace the valve assembly P17 3 Valve spring is damaged Replace the valve spring P17 4 The valve is fixed in an opened position Clean the valve s...

Страница 16: ...gm is damaged Replace the diaphragm assembly P16 1 Product without backflow function is used Check the product number if backflow function is equipped P8 2 Foreign materials caught in the sliding part...

Страница 17: ...spring and diaphragm assembly in that order 4 Assemble the diaphragm assembly pressure regulating spring and then pressure regulating screw assembly Direction of diaphragm assembly and pressure regul...

Страница 18: ...with a precision screwdriver Precision screwdriver 4 Remove the valve spring 5 Remove the valve assembly Assembly 6 After replacing the removed components with new components place them into the regul...

Страница 19: ...e to the regulator with the mounting screws and tighten the screws referring to the tightening torque specified in the right column Phillips screwdriver Tightening torque 0 85 0 05 N m 5 Mount the pre...

Страница 20: ...te correctly Presence of the O ring 3 Mount the blanking plate Mount the blanking plate to the product with the mounting screws and tighten the screws referring to the tightening torque specified in t...

Страница 21: ...mes out or is left on the regulator mount the O ring to the check valve assembly correctly Presence of the O ring 4 Mount the check valve cover Mount the check valve cover to the product with the moun...

Страница 22: ...sembly 2 Assemble the plug assembly Hexagon wrench Nominal size 4 Tightening torque 0 6 0 05 N m Note Applicable to the product without pressure gauge 21 Procedure AR20 AR20K AR30 AR30K AR40 AR40K AR5...

Страница 23: ...ng comes out or is left on the regulator mount the O ring to the plug assembly correctly Presence of the O ring 3 Assemble the plug assembly Assemble the plug assembly to the product with the mounting...

Страница 24: ...3 Cross recessed round head screws 4 pcs Bonnet Pressure regulating screw assembly Pressure regulating spring 8 Diaphragm assembly Body 7 Valve assembly Valve spring 9 Valve guide assembly Cover Cap I...

Страница 25: ...uct swap all parts for the front and back When swapping 4 Square embedded type pressure gauge and 6 Digital pressure switch tighten them with 0 85 0 05N m Tighten others with 0 6 0 05N m Mounting scre...

Страница 26: ...5N m Tighten others with 0 6 0 05N m Square embedded type pressure gauge O ring 5 Pressure gauge cover O ring 2 pcs Check valve assembly Product Check valve cover 3 Pressure gauge round type Pressure...

Страница 27: ...40 46 6 5 8 53 2 3 31 3 38 5 19 7 AR40 D 50 54 54 8 5 10 5 70 2 3 35 5 42 5 21 7 AR40 06 D 50 54 55 5 8 5 10 5 70 2 3 37 42 5 21 7 AR50 D 70 75 66 11 22 113 3 2 AR60 D 70 75 66 11 22 113 3 2 26 1 8 1...

Страница 28: ...D 50 54 54 8 5 10 5 70 2 3 35 5 42 5 21 7 AR40 06 D 50 54 55 5 8 5 10 5 70 2 3 37 42 5 21 7 AR50 D 70 75 66 11 22 113 3 2 AR60 D 70 75 66 11 22 113 3 2 27 Optional specifications Standard specificati...

Страница 29: ...D 41 40 46 6 5 8 53 2 3 31 3 38 5 19 7 AR40K D 50 54 54 8 5 10 5 70 2 3 35 5 42 5 21 7 AR40K 06 D 50 54 55 5 8 5 10 5 70 2 3 37 42 5 21 7 AR50K D 70 75 66 11 22 113 3 2 AR60K D 70 75 66 11 22 113 3 2...

Страница 30: ...Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the par...

Отзывы: