T
ROUBLESHOOTING
A-2
Diagnosing Power Problems with the LEDs
The Power and RPU LEDs work in combination to indicate power status as
follows.
Link/Act LED
is Off
• Verify that the switch and attached device are powered
on.
• Be sure the cable is plugged into both the switch and
corresponding device.
• If the switch is installed in a rack, check the connections
to the punch-down block and patch panel.
• Verify that the proper cable type is used and its length
does not exceed specified limits.
• Check the adapter on the attached device and cable
connections for possible defects. Replace the defective
adapter or cable if necessary.
Table A-2 Power/RPU LEDs
Power LED RPU LED Status
Green
Green
Internal power functioning normally; RPU is present.
Green
Amber
Internal power functioning normally; RPU plugged in
but faulty.
Green
Off
Internal power functioning normally; RPU not plugged
in.
Amber
Green
Internal power faulty; RPU delivering power.
Off
Off
Both internal power and RPU unplugged or not
functioning.
Table A-1 Troubleshooting Chart