Auto-shift function (F 5)
When there are large fluctuations in the supply pressure, the switch
may fail to operate correctly. The auto-shift function compensates
such supply pressure fluctuations. It measures the pressure at the
time of auto-shift signal input and uses it as the reference pressure
to correct the set-value on the switch.
Auto-shift zero
The basic function of auto-shift zero is the same as the function for
auto-shift. Also, it corrects values on the display, based on a
pressure value of “ ”, when the auto-shift is selected.
Set-value correction by auto-shift function
Compound pressure
Vacuum pressure
Positive pressure
Regulating pressure range
–15.22 to 15.22 psi
1.45 to –15.23 psi
–15.2 to 152.3 psi
Possible set range
Possible Set Range for Auto-Shift Input
–30.4 to 30.4 psi
16.68 to –16.68 psi
–167.5 to 167.5 psi
J
Power-saving mode (F80)
Power-saving mode can be selected.
It shifts to the power-saving mode without button operation for 30
seconds. It is set to the normal mode (Power-saving mode is OFF.)
when ex-factory. (Decimal points and operation indicator light (only
when the switch output is turned ON.) blink in the power-saving
mode.)
K
Secret code setting (F81)
It can be set whether secret code input is required or not when key is
locked. It is set to input no secret code when ex-factory.
∗
Rectified value
When the auto-shift is selected, “ ” will be displayed for about 1
second, and the pressure value at that point will be saved as a
rectified value “ ”. Based on the saved rectified values, the set-
value
Note)
of “ ”, “ ”, “ ”, and “ ” will likewise be rectified.
Note) When an output is reversed, “ ”, “ ”, “ ”, “ ” will be
rectified.
The F
in ( ) shows the function code number. Refer to the Operation
Manual for the details of operation procedures and function codes.
Function Details
Supply pressure
normal
P-1
(P-3)
ON
OFF
Hi
Lo
Auto-shift
input
H-1
(H-2)
A
Supply pressure
drop
B
Supply pressure
increase
Switch output
response time
when auto-
shift is input.
5 ms or more
10 ms or less
Pressure
(Differential)
Rectified
value
∗
Rectified value
∗
Switch
output
1·(2)
16
Series
ZSE40A(F)/ISE40A