I
NSTALLING
THE
S
WITCH
3-3
Mounting
A TigerStack 100 unit can be mounted in a standard 19-inch equipment
rack or on a desktop or shelf. Mounting instructions for each type of site
follow.
Installing Optional Modules
: Before mounting the switch, be sure you
install any optional modules. If you have purchased an optional slide-in
100BASE-FX or 1000BASE-X media expansion module, or Stack Module,
install these modules now, following the instructions included with the
package.
Rack Mounting
Before rack mounting the switch, pay particular attention to the following
factors:
◆
Temperature: Since the temperature within a rack assembly may be
higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range. (See page C-2.)
◆
Mechanical Loading: Do not place any equipment on top of a
rack-mounted unit
◆
Circuit Overloading: Be sure that the supply circuit to the rack
assembly is not overloaded.
◆
Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than
direct connections to the mains.