A-1
A
PPENDIX
A
T
ROUBLESHOOTING
Diagnosing Switch Indicators
Troubleshooting Chart
Symptom
Action
Power LED is Off
•
Internal or redundant power supply has failed or is
disconnected.
•
Check connections between the switch, the power cord,
the wall outlet.
•
Contact SMC Tech Support.
Link LED is Off
•
Verify that the switch and attached device are powered
on.
•
Be sure the cable is plugged into both the switch and
corresponding device.
•
Verify that the proper cable type is used and its length
does not exceed specified limits.
•
Check the adapter on the attached device and cable
connections for possible defects. Replace the defective
adapter or cable if necessary.
1000BASE-T port is
not functional
•
Verify that the RJ-45 cable is plugged properly on the
front panel M2 port.
•
Check the M2 module is unplugged on the rear panel.