Resetting the Switch
Figure 4-15. Reset Screen
This screen provides the following options:
1. Highlight “
Reset
” in the Main Menu and press <ENTER> to
access the reset screen (Figure 4-14).
2. Highlight “
Display Diagnostics While Power-On
” and
press <ENTER> to enable/disable diagnostic indicators
during a reset.
3. Highlight “
Reset Unit with Diagnostics
” or “
Reset Unit
without Diagnostics
” and press <ENTER> to enable or
disable diagnostic tests, respectively, during a reset.
4. Highlight “
Clear Address Table
” and press <ENTER> to
clear the address table of a single port or the whole switch.
Use arrow keys to cycle through selections (Ports 1-8 or the
whole switch). Press <ENTER> to confirm the choice.
5. Highlight “
Reset EEprom to Factory Default Value
” and
press <ENTER> to clear all counters and restore factory
default settings for all configuration parameters. The system
will ask for confirmation. Press <ENTER> to confirm and
initiate.
CONFIGURATION AND MANAGEMENT
4-30
Reset
Display Diagnostics While Power-On
Reset Unit with Diagnostics
Reset Unit without Diagnostics
Clear Address Table
Reset EEprom to Factory Default Value
Use cursor keys to choose item. Press <ENTER> to confirm choice.
Press <CTRL><N> to return to the Main Menu.