Error Codes

Error codes will appear on the HOME page when there is an electronic fault in 
the system. If there are multiple faults the error codes will cycle to the next code 
every 5 seconds.

Code

Description

Actions

E0000

Communication Error Between 
TSC and Ceiling Controller

Ensure connection between 
touchscreen controller and ceiling 
controller is correct and secure, 
and cable is not damaged.

E0001

Clock Error

Change the time on the TSC.

E1080

Outside Sensor Com Failure

Ensure connection between 
sensor and ceiling controller 
is secure, and cable is not 
damaged.

E1180

Roof Sensor Com Failure

E1280

Lounge Sensor Com Failure

E1380

Bedroom Sensor Com Failure

Contact SmartVent for support on 0800 140 150 if you see error codes not listed 
above or the actions above do not clear the errors.

Содержание Evolve 2

Страница 1: ...Your guide to a healthier home HOME VENTILATION SYSTEMS SYN190E2 User Manual...

Страница 2: ...ies or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to...

Страница 3: ...reen 10 Home Screen 10 Home Screen Icons 11 Settings 13 Date Time 14 Filter 15 General Settings 16 Settings Interface 17 Ventilation 18 Heat Transfer 21 Tempering Heater 24 Core Bypass 27 Recycle 28 M...

Страница 4: ...cess heat from your lounge to your bedrooms Tempering Heaters Designed for situations where supply air temperatures are too cool Core Bypass Adds the ability for the system to bypass the recovery core...

Страница 5: ...5 Quick Setup Guide 1 Switch On Power on the system with the power button 2 Unlock the Touchscreen Press and hold the lock icon for 5 seconds in the bottom left corner of the screen to unlock...

Страница 6: ...25 10 41 JUN 2019 26 Quick Setup Guide cont d 3 Set the Clock Press the settings icon on the home screen Select the DATE TIME icon Scroll and select the current date and time Press the save icon to sa...

Страница 7: ...t quality air from either the roof cavity or the outside Quick Setup Guide cont d 4 Set Ventilation Mode and Temperature From the home screen press the settings icon Select the the VENTILATION icon Se...

Страница 8: ...8 Screens and Navigation STANDBY SETTINGS HOME DATE TIME FILTER GENERAL VENTILATION HEAT TRANSFER HEATER SETTINGS...

Страница 9: ...smartvent co nz DATE TIME SETTINGS TIME DATE 08 39 APR 2017 24 09 40 MAY 2018 25 10 41 JUN 2019 26 GENERAL SETTINGS ADVANCED SETTINGS CON CT SMARTVENT NQUI CONTACT SMARTVENT ENQUIRY SMARTVENT CO NZ 08...

Страница 10: ...r is first powered on the standby screen will be shown Press the standby icon in the middle of the screen to turn the system on Home Screen If the screen is locked press and hold the lock icon for 5 s...

Страница 11: ...OUNGE or BEDROOM Good Poor Outdoor Temperature Room Selection tap to select and view either LOUNGE or BEDROOM conditions Lock Button tap and hold for 5 seconds to lock and unlock Ventilation Mode AUTO...

Страница 12: ...ON Filter Indicator2 check filter settings to see which filter needs to be changed Good Change Recovery Core State Heat Energy Recovery Core Bypass1 Tempering Heater1 Tempering Heater required for thi...

Страница 13: ...s menu by pressing any of the menu icons Note Heat transfer and Heater icons will not be visible if these upgrades1 are not installed 1 For more information about SmartVent system upgrades contact 080...

Страница 14: ...ll and select the current date and time 4 Press the save icon to save your changes 5 Press the home icon to return to the home screen Note Time needs to be manually changed when daylight saving begins...

Страница 15: ...and navigate to the FILTER SETTINGS screen press the F7 filter RESET icon and press the Save icon to reset the filter timer Caution Always install a genuine SmartVent filter to protect your system Sm...

Страница 16: ...e from 30 seconds to 10 minutes AUTO SCREEN LOCK Check this box to allow the screen to lock and enter a low power state when the timeout setting is reached Note When the box is unchecked the screen wi...

Страница 17: ...elect a field to modify Scroll and select your desired option Press the tick to confirm your selection or cross to cancel Press save icon to save changes Press return to previous screen icon to the se...

Страница 18: ...ergy2 system chooses where to draw air from and at what speed depending on indoor dew point and temperature levels in that order Your lounge and bedroom moisture levels have the highest priorities in...

Страница 19: ...1 Speed fan To configure multiple days at the same time press MULTI SELECT then choose the days you want to configure and then proceed as above Settings will be applied to all days selected Press Save...

Страница 20: ...allows manual control of fan speed and air source if required Fan speeds can be altered manually by pressing tapping either of the fan speed icons Press Save icon to save changes VENTILATION HEAT TRAN...

Страница 21: ...ventilated we recommend you use the timer function to turn HEAT TRANSFER OFF during the day the middle of the night and early morning We also recommend HEAT TRANSFER is set to AUTO in the evening OFF...

Страница 22: ...t Synergy2 system will revert to VENTILATION mode temporarily while the lounge is cooler than this temperature Scroll and select the minimum temperature you want in your lounge before your system comm...

Страница 23: ...ng We also recommend HEAT TRANSFER is set to AUTO in the evening ON Mode HEAT TRANSFER is on regardless of lounge temperature OFF Mode HEAT TRANSFER is always off System is in Ventilation Mode AUTO Mo...

Страница 24: ...to take the chill off incoming air When the TEMPERING HEATER is active the fans will run at a fixed medium speed The TEMPERING HEATER is not designed to warm your home OFF Mode The TEMPERING HEATER is...

Страница 25: ...TO Mode If a TEMPERING HEATER is installed the heater turns on when the fresh air temperature is cooler than the set temperature Press Save icon to save changes VENTILATION HEAT TRANSFER HEATER HEATER...

Страница 26: ...OFF during the day and evening and set to AUTO overnight and early morning ON Mode TEMPERING HEATER is on regardless of temperatures OFF Mode TEMPERING HEATER is always off AUTO Mode TEMPERING HEATER...

Страница 27: ...matically when the fresh air can help improve the indoor temperature For example when the indoor air is warmer than your set temperature and the fresh air is cool the core bypass will automatically tu...

Страница 28: ...t of damp fresh air entering your home If you have a Heat Transfer Kit1 installed you can set the recycle fan speed in the AUTO VENTILATION Mode page RECYCLE SPEED is your fan speed when your system i...

Страница 29: ...n Filter Grade Order Code Typical Life F7 FAN2093 12 months F7 Carbon1 FAN2277 6 months HEPA Carbon1 FAN2278 6 months Caution When switching to a different grade of filter remember to modify the KITS...

Страница 30: ...next step 2 Remove the front panel black plastic cover from the recovery ventilator 3 Carefully remove the two filter access covers 4 Locate and carefully remove the 2 x G3 filters as pictured 5 Gent...

Страница 31: ...unit and put to one side 3 Carefully remove the exchanger core 4 Create a mild detergent solution 1 x teaspoon of washing up liquid to a 9L bucket of warm water Soak the heat exchanger core in this li...

Страница 32: ...s no air coming out my diffusers below 4 To increase the velocity of air coming into the room reduce the diffuser opening to 5 10mm There is no air coming out my diffusers 1 Check that the touchscreen...

Страница 33: ...n still shows as after changing the filter 2 Filter reset required see the filter section on page 25 for instructions The scheduler is not switching at the right time 1 The system has up to a 5 minute...

Страница 34: ...between touchscreen controller and ceiling controller is correct and secure and cable is not damaged E0001 Clock Error Change the time on the TSC E1080 Outside Sensor Com Failure Ensure connection be...

Страница 35: ...to other areas via the SmartVent fan ducting system Intake Grille An attachment to the ducting to prevent large objects being drawn into your system In a SmartVent system it is usually the white squa...

Страница 36: ...ve load Controller Operating Temperature 0 to 50 C Controller Operating Humidity 5 90 non condensing Sensor Operating Temperature 20 C to 70 C Sensor Operating Humidity 5 90 non condensing Live Output...

Страница 37: ...37 Notes...

Страница 38: ...38 Notes...

Страница 39: ...ed PO Box 14 347 Panmure Auckland NZ Technical Support 09 259 1662 e enquiry smartvent co nz w www smartvent co nz Specifications are subject to change without notice PUB1462 1809 Contact 0800 140 150...

Отзывы: