Smartswitch FC-006 Скачать руководство пользователя страница 6

 

6

 

 
 
 
 
 

Operation For Normal Mode:

 

(Rotary switch in position 0)

 

 

 
 
Manual:

 

When switched to Manual Mode the engine room fans will turn On and stay On until 
turn Off or placed in Auto Mode. 
 

 
Off:

 

All fans Off 

 

 
Auto:

 

When placed in Auto Mode and the engine starts the Fans will start after the 
programmed “Fan Start Time” (see page 6) both Fans will run in the same direction.  
 
If the Lazz fan is On it will be turned Off and placed in standby mode the Lazz On 
LED will be flashing to indicate this, all Lazz times will be saved and suspended. 
 
When the engine is stopped both Fan 1 and Fan 2 will be turned Off for the 
programmed “Fan Stop Time” (see page 6) then both Fans will start again but Fan 2 
will be reversed. The Fans will stay on until the programmed “Fan Run On Time” (see 
page 6) at which time they will both turn Off. 
 
If the Lazz was On and placed in standby, it will now resume its normal operation. 

 
 
 
 
Emergency Stop: 

If this input is triggered ALL Fans will be turned Off and the LED will turn On. 

 
 
Emergency Stop: 

If this input is triggered ALL Fans will be turned Off and the LED will turn On.

 

 
 
 
 
 
 
 
 
 
 

Содержание FC-006

Страница 1: ...1 SMART SWITCH TECHNOLOGIES FC 006 Engine Room Fan Controller Installation Manual...

Страница 2: ...Batt Batt Comms Comms To Keyboard Batt Batt Logic power supply Fan Supply Fan 1 Fan 1 Fan 2 Fan 2 Fan 3 Fan 3 Fan Supply Fan Supply Fan Supply Engine Room Reversable Either connector may be used Eith...

Страница 3: ...normally open or normally closed input switch If the input switch is normally open install the jumper if normally closed removed the jumper Emergency Fire Stop Input Switch Link Setup for clean relay...

Страница 4: ...Setup for clean contacts Note The Link could also be a relay contact from an engine running signal In which case the oil pressure input will only be looked at if the engine is running 1 2 3 4 Oil Pre...

Страница 5: ...n Auto Off Manual Fans On Off LED This LED will be on green only when the engine room fans are actually ON and off red when the fans are OFF Emergency Stop Fire LED S These LEDS will be on red if the...

Страница 6: ...On LED will be flashing to indicate this all Lazz times will be saved and suspended When the engine is stopped both Fan 1 and Fan 2 will be turned Off for the programmed Fan Stop Time see page 6 then...

Страница 7: ...stopped the Fans will stop for the Fan Stop Time and then turn back on but with Fan 2 reversed Turn the rotary switch to position A Push the program switch the LED will flash for every key push Each p...

Страница 8: ...tate System default On State Lazz Start On Rotary switch to position 8 Turn the rotary switch to position 8 Push the program switch the LED will flash Switch the rotary switch back to position 0 Lazz...

Страница 9: ...turned of if activated Operation If either engine run signal is triggered fan output 1 2 and 3 will turn ON and stay on until both engine run signals are off then fan output 3 will turn OFF and fan o...

Страница 10: ...k to position F Programming the Lazz On Time Rotary switch to position 4 Turn the rotary switch to position 4 Push the program switch the LED will flash for every key push Each push will increase the...

Отзывы: