SMARTSCAN MAGSAFE 785093 INSTALLATION SHEET GUIDE
CD229/230707
13
H
EStop Board
The Estop board is fitted as standard and allows the user to connect an
external emergency stop device to the Magsafe control unit. Activation of the
Estop removes power to the control unit and magnets. The Estop board is
used for connecting power to the system even if the Estop function is not
being used.
The Emergency stop function is selected via the jumpers J1 and J2 on the E
stop board shown above. Position the jumper on J2 if the Estop function is
required or on J1 if not required.
Estop board showing jumpers J1 and J2
Note:
In addition to these are 2 other jumpers located directly above the
main control board. Please set these jumpers to the ‘ON’ position as well
if the Estop function is required. Position pin 1 and 2 = ‘ON’ and position
pin 2 and 3 = ‘OFF’. The jumpers on both the main PCB board and the E
stop board must be in the same condition, either Estop selected or not
selected.