7 0 0 0 S E R I E S
Fig. Q shows connection details for initiation of 1, 2 and 3 beam floating
blanking.
If floating blanking is NOT required terminals J1/7, J1/8, J1/9 and J1/10
should not be connected.
If for example, 1 beam floating blanking is required connect J1/7 to the
24V DC supply and J1/8 to 0V via switch contacts.
The number of beams blanked can be changed during operation.
Switching between beam blanking inputs can be achieved manually
with a mode switch or automatically via a PLC etc.
INSTALLATION SHEET
35
Note:
N = 30mm. This refers to the use of floating blanking with light
curtains of 30mm Object Detection Capability (ODC) ONLY. Please
refer to page 7 of this handbook for the section on floating blanking.