Wiring
A checklist must be completed during the drive wiring process. See Appendix 1 for terminal
location.
Power
Perform the following to connect power. See
C4 Controller
sheet
03 Machine Room
for job
specific information.
Connect main line power to terminal blocks L1/L2/L3.
Connect the ground wire to the yellow/green terminal block next to L1-L3.
Brake
Perform the following to connect the brakes. See
C4 Controller
sheet
05 Brakes
for job specific
information.
Connect the main brake wiring to terminal K1 / K2 and the secondary brake wiring (if
equipped) to terminals J1 / J2 located on the terminal block next to the M Contactor.
Motor / Encoder
Perform the following to connect the drive to the motor and encoder cable. See
C4 Controller
sheet
4 Motor
and Drive Connections
for job specific information.
Connect motor leads to the M contactor at T1/T2/T3.
Connect the encoder cable to the encoder cable mounted on the drive.
The table below lists the Wiring References for Common Encoders.
Table 1: Wiring References for Common Encoders
Encoder Imperial / PG-X3
Magil
IH740 / IH950 Accucoder Wachendorff
Industrial
Encoder
(Canada)
PWR
Red (2)
Red (2)
Brown (2)
Brown
Brown
Brown
COM
Black (1)
Black (1)
White (1)
Blue
White
(Shield)
White
A
White (3)
White (3)
Green (3)
White
Green
Green
/A
Black/White
(6)
Brown (6)
Pink (6)
Green
Red
Pink
B
Blue (4)
Green (4)
Yellow (4)
Yellow
Yellow
Yellow
/B
Red/Black (7)
Blue (7)
Blue (7)
Gray
Black
Blue
Z
Orange (5)
Yellow (5)
Gray (5)
Gray
Gray
/Z
Green (8)
Orange (8)
Red (8)
Violet
Red
DAT