Battery Removal (SBP400-800)
Before replacing the battery, turn off the UPS
and unplug the UPS cord from the wall outlet.
Follow Chart 1 to remove the screw located
on the bottom of the front panel and then open
the front cover.
After removing the front cover, follow Chart 2 to remove partition by removing the
screw. Then follow Chart 3 to pull out battery by pulling
attached white vinyl sheet.
Disconnect the wires connected to the battery. Be sure to replace the same type of
batteries and dispose of old batteries properly at an appropriate recycling facility.
Chart 1
Chart 2
Screw
Partition
Chart 3
7