CAUTION 

 

UV light may cause irritation to the skin and/or eyes.  Avoid exposure.  

 

DANGER – ULTRAVIOLET RADIATION – disconnect power before replacing lamp. 

 

Prolonged or repeated exposure to UV light may have adverse physical effects including, severe 
damage to your skin and eyes.  Seek immediate medical attention for overexposure to UV radiation. 

 

Keep the cord away from high temperatures or other heat sources. 

 

Do not lift the light or the transformer by its power cord. 

 

This light assembly has not been investigated for use in swimming pools or hot tubs. 

 

PREPARATION 

Before beginning assembly

 

of product, make sure all parts are present. Compare parts with package 

contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or 
operate the product. Contact customer service for replacement parts. 

 

Estimated Assembly Time: 30 minutes  

 

No Tools Required for Assembly

 

 

IMPORTANT NOTES 

 

This product will not operate unless it is fully assembled with the lamp base screwed completely into 
the housing.   

 

UV rays are harmful to your eyes and skin.  The indicator portal will remove the harmful effects of the 
UV light but still allow you to see the bulb operating. 

 

Do not attempt to operate this product unless the lamp is completely assembled within the light 
housing. 

 

This product conforms to the Code of Federal Regulations (CFR) requirements including, Title 21, 
Chapter 1, Subchapter J, Radiological Health. 

 

 

 

 

 

 

 
 
 
 

ASSEMBLY INSTRUCTIONS 

 

1.  Remove the light assembly from the package and untie the 

power cord.  Rotate the locking ring counterclockwise to 
remove the lamp holder.  Fig. 1 

 

 
 
 
 
 
 
                                                                                                                                        Fig. 1 
 
 
 

Specifications 

Lamp Voltage 

60V 

Lamp Current 

0.2A 

Lamp Power 

9 W 

Rated Frequency 

60 Hz 

UV Irradiance 

35 µW/cm

2

 

Bulb Life 

8000 hours 

Bulb Model Number 

PCRB 

UV Wave Length 

UV(C) · 254 nm 

 

 

Locking 

ring 

C

Содержание PCUV9

Страница 1: ... protected by a ground fault circuit interrupter GFCI Risk of Electric Shock Do not use the UV filter if the quartz tubing around the lamp is broken Immediately unplug and seek an authorized repair service or discard the unit GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or break down grounding will reduce the risk of electric shock by providing a path of lea...

Страница 2: ... operate the product Contact customer service for replacement parts Estimated Assembly Time 30 minutes No Tools Required for Assembly IMPORTANT NOTES This product will not operate unless it is fully assembled with the lamp base screwed completely into the housing UV rays are harmful to your eyes and skin The indicator portal will remove the harmful effects of the UV light but still allow you to se...

Страница 3: ...ubing from the outlet of your pump to the inlet of the PCUV9 The adapters included can connect to 1 2 in 3 4 in or 1 in tubing Note that 1 2 in tubing is recommended for optimum performance Fig 4 NOTE The inlet is marked IN on the lamp housing Fig 4 5 Connect tubing to the outlet of the PCUV9 The other end can be connected to a spitter waterfall or any other water feature for your pond Fig 5 NOTE ...

Страница 4: ...1 Disconnect the UV light from the outlet Be sure to allow sufficient time for the light to cool before disassembling the light Fig 7 Fig 7 2 Rotate the locking ring counterclockwise to remove the lamp holder B Fig 8 Fig 8 3 Carefully remove the old bulb by firmly pulling on the base Carefully install the new bulb Fig 9 Fig 9 Locking Ring Old bulb New bulb B C B GFCI ...

Страница 5: ...the light to cool before disassembling the light 2 Unscrew the locking ring and pull out the light unit 3 Carefully pull out the glass tube holder by twisting and then pull out 4 Use warm soapy water to clean the glass tube Be sure to use biodegrable soap 5 Reassemble the PCUV9 and be sure that all gaskets and o rings are seated properly TROUBLESHOOTING If the light fails to operate Check to make ...

Страница 6: ...artment at 1 888 755 4497 8 a m 6 p m EST Monday Friday Printed in China Part Description B Lamp holder C Lamp housing D Adapter E Adapter nut F Adapter gasket G O ring 1 H O ring 2 I Lamp holder gasket K Glass tube L Glass tube holder M Glass tube locking nut I B L G H K M F C D E smartpond replacement UV bulbs can be purchased at Lowe s model PCRB ...

Страница 7: ...e inspected to determine cause of failure before warranty is applied Warranty does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any othe...