after the decimal point;   
These electrical parameters result will be reported to the Z-Wave

 controller regularly through the 

Meter  Report  of  Meter  Command  Class,  the  interval  of  which  can  be  configured  by  the  user  by 
means shown in "

Configuration: No.11

The  device  also  provides  the  function  of  reporting  the  measurement  results  to  the  Z-Wave

 

controller  when the  load  current  changes  and the  user  can  set  the  changed quantity of  the  load 
current freely by means shown in “Configuration

: No.10

The electric quantity detection result is reported to Command Class

 

Command Class 

Command 

Scale 

Precision 

COMMAND_CLASS_METER  METER_REPORT 

kWh 

0.01kWh 

Watt 

0.01W 

Volt 

0.01V 

Ampere 

0.01A 

The  max  cumulative  energy  is 

21474836.47

kWh,  if  it  is  over  this  value,  it  will  be  back  to  0kWh 

automatically. 

Reset Cumulative Energy 

There have two ways to reset cumulative energy: 
1  Z-Wave  gateway  send  METER_RESET  command  to  SmartPlug  to  reset  the  cumulative  energy 
value. 
2 Execute the factory reset operation to reset the cumulative energy value. 
 
The  cumulative  energy  will  not  be  reset  if  SmartPlug  remove  from  Z-Wave  Network  by  exclusion 
operation. 

Over-current Protection 

The outlet can provide a maximum load current of 16A, and when the load current exceeds 16A, the 
load power supply will be automatically cut off. And it will inform the host of the overload of the 
outlet through NOTIFICATION_REPORT of the Notification Command Class, and meanwhile, the LED 
light of the outlet will flash with an interval of one second; Users can remove the overload alarm by 
pressing the button or sending SWITCH_BINARY_SET=0xFF, and for safety's sake, before that, users 
should remove the load from the outlet first. 
 
Users  can  control  the  maximum  output  current  of  the  outlet  by  setting  the  maximum  output 
current, the setting method of which is shown in "

Configuration: No. 8

". 

 
Overload protection communication Command Class 

Command Class 

COMMAND_CLASS_NOTIFICATION 

Command 

NOTIFICATION_REPORT 

Type 

NOTIFICATION_TYPE_POWER_MANAGEMENT (0x08) 

Event 

NOTIFICATION_EVENT_POWER_MANAGEMENT_OVERLOAD_DETECTED (0x08) 

Содержание 1Led

Страница 1: ...tPlug 1Led User Manual Z Wave 700s S2 Version Version Written By Date Change List 1 0 Yongqi 20201022 Initial 1 1 Yongqi 20210116 Fixed Some Error Descriptions 1 2 Yongqi 20210304 Add Note for OTA Led...

Страница 2: ...f Blue led will blink with 1s interval until inclusion successful Remove 1 Power up the device 2 Set Z Wave Controller into exclusion mode 3 Press and hold the button for 5s until Blue led lights is o...

Страница 3: ...CLASS_INDICATOR COMMAND_CLASS_DEVICE_RESET_LOCALLY SWITCH_BINARY_REPORT NOTIFICATION_REPORT METER_REPORT INDICATOR_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION 2 Control COMMAND_CLASS_BASIC BASIC_SET Devi...

Страница 4: ...ive energy value 2 Execute the factory reset operation to reset the cumulative energy value The cumulative energy will not be reset if SmartPlug remove from Z Wave Network by exclusion operation Over...

Страница 5: ...ize Byte Available Settings Default value 1 1 0 1 1 2 Button Switch Function Disable Setting this configuration as 0 will be disabling to turn on and off the relay by pressed button Parameter Number S...

Страница 6: ...nt setting This configuration sets the maximum output current that the device can provide When the current consumed by the load is greater than the setting value the device will automatically cut off...

Страница 7: ...itch Set 0 3 Basic Set 1 99 maps to Binary Switch Set 255 4 Basic Get Report maps to Binary Switch Get Report SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the...

Страница 8: ...Support Yes No SECURITY_KEY_S0 Yes SECURITY_KEY_S2_UNAUTHENTICATED Yes SECURITY_KEY_S2_AUTHENTICATED Yes SECURITY_KEY_S2_ACCESS No All Supports Command Class in Each NIF Lists Command Class Version N...

Страница 9: ...with S0 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported non securely And when device is included with S2 level COMMAND_CLASS_MANUFACTURER_SPECIFIC is supported securely only Notice 2 Indicates...

Страница 10: ...Z Wave Network Send NIF Blink with 1s Interval Add to Z Wave Network Blink with 300ms Interval OTA is Running Note 1 The LED State is Not Changed when Led Is Busy On or Blink Such as Relay on Over Cu...

Отзывы: