background image

SMARTLINK LUX–TWR RADIO PIR MANUAL

PAGE 3

FUNCTIONAL 'SYSTEM' TESTING

A system test should be done by physically walking 

across the LUX–TWR coverage pattern while the system 

is fully armed.  NOTE: Allow time for the Sleep Cycle 

Timer to expire before testing.  Always notify the Cen-

tral Monitoring Station prior to performing any testing.  

WALK TEST

Walk test is a way to verify that the sensor is operating 

as desired and in the optimum location.  Slow and short 

steps should be taken across the coverage zones in 

both directions.  When motion is detected, the White 

LeD should blink once followed by a quick blink of the 

green RF ACK LeD.  The green LeD indicate that the 

sensor transmitted an alarm signal an that the control/

transceiver acknowledged that transmission.  See 

paragraph titled: RF ACKnowledge LED

NOTE: Walk Test mode bypasses the Sleep Cycle timer 

allowing the Sec./Convenience LeD and the RF ACK 

LED to operate regardless of DIP switches 2, 3, and 4.  

SeNSOR WALK TeST

 

This is started by opening and closing the sensor 

housing to violate the tamper switch.  Sensor Walk 

Test will end after 10 minutes.  

RF ACKnowledge (Green) LED

This LeD is located in the clear lens on the sensor front.  

It's a bi-Colour LeD providing visual status of the two-way 

acknowledge (response) from the control/transceiver.  

In bright lighting conditions this LED may be difficult 

to see.  DIP Switch #2 allows the green LeD to be 

disabled for all operations except the Walk Test Mode.  

GREEN blink = 

Sensor has successfully transmitted a 

violation (alarm) transmission to the transceiver and 

that signal has been received and acknowledged by 

the transceiver.  The green blink is not provided for 

a sensor restore transmission.. 

    

ORG/RED blink = 

Sensor was not successful in trans-

mitting after multiple attempts.    

 

DISABLING RF ACKnowledge (Green) LED

DIP Switch #2 allows the RF ACKnowledge (green) 

LeD to be disabled for regular operation, helping pre-

vent unauthorized persons from learning the coverage 

patterns.  It also helps extend battery life.  Place DIP 

Switch #2 in the "NO" position to disable the RF ACK 

LED, or in the "YES" position to enable the RF ACK LED.

NOTES: DIP Switch #2 does not disable this LED from 

working in the Walk Test Mode.  

Creep Zone

"Lookdown"

Security/

Convenience 

LED (White)

RF ACK 

Bi-Colour LED 

(Green + Org/Red)

 

Figure 6. Front View of Sensor

COVERAGE PATTERNS

Figure 1.  Top and Side Views 

(assumes range is set to "HI")

2.1m

0.3m

1m

3m

6m

15m

6.  After enrolling the sensor into the control and setting 

the Option Switches, reposition sensor over the 

back housing and snap it into place.  This action 

will activate the Walk Test mode for the next 10 

minutes.  Perform an immediate Walk Test accord-

ing to the procedure that follows. 

7.  If the swivel mount bracket was used then it will be 

possible to adjust (fine tune) the Sensor coverage.  

If the swivel bracket was not used, and the sensor 

was fixed mounted to the wall, the coverage pattern 

is based on the mounting height and position.

8.  After Walk Testing has been completed, secure 

the sensor to the back housing using the locking 

screw provided (small countersunk screw).

PULSE COUNT (Switch 6)

Sensor must detect 1 or 2 events in the 

coverage area before an alarm is created. 

FUTURe (Switch 1)

Sensor  must  detect  3  or  4  events  in  the 

coverage area before an alarm is created.

RANGE (Switch 5)

Sensor is set for the shorter detection range 

(approximately 12m.) 
Sensor is set for the longest detection range 

(approximately 15m.) 

To extend battery life, a mandatory sleep cycle (2 time 

settings) begins after each alarm transmission.  After 

the Sleep Cycle expires, there must be ~8 seconds of 

quiet (no movement) before the sensor will be allowed 

to detect and send another radio transmission.  

Long (120 secs.)  Until this timer expires 

the sensor cannot transmit another event.

SECURITY/CONVENIENCE LED (Switch 3)

This switch is not currently used.

Short  (30  secs.)    Until  this  timer  expires 

the sensor cannot transmit another event.

Sec/Convenience LED is NOT ENABLED 

except for the Walk Test.

Sec/Convenience  LED  is  ENABLED  for 

other functions other than Walk Test and 

audible alarms.  See back page for details.

RF ACK LeD (Switch 2)

RF ACK  (Green)  LED  is  NOT  ENABLED 

except during the Walk Test Mode.

RF ACK  (Green)  LED  is  ENABLED,  and 

should blink green upon a detect and 

positive acknowledgment from the control. 

SLEEP CYCLE (Switch 4)

5. 

DIP SWITCH OPTION SETTINGS

Green =  Sensor transmitted and received a positive 

ACK (acknowledgment) from the Control/

Transceiver.  

Org/Red = Sensor attempted to transmit but did not 

receive an ACK (acknowledgment) from the 

Control/Transceiver. 

Figure 7.  DIP Switches

1 - 2

HI

SH

YES

NO

N/A

3 - 4

LO
LG

NO

YES

N/A

PuLSE COuNt

RANGE

SLEEP CYCLE

SEC/CONv. LED

RF ACK. LED

FutuRE uSE

*Factory default, all off

ON

OFF*

1 - 2

HI

SH

YES

NO

3 - 4

LO

LG

NO

YES

N/A

ANTI-TAMPER SWITCH

This switch detects the separation of the front housing 

from the backplate, resulting in a signal being transmitted 

to the control/transceiver that will cause the associated 

zone to become violated.  Snapping the front housing 

back onto the backplate will transmit a restoral.

 

  

A deluxe 90° swivel bracket may be purchased and 

used in lieu of the standard swivel bracket.  This bracket 

has a short extended arm and allows the sensor to be 

aimed at up to a 90° offset from the wall or base.  This 

bracket also allows the sensor to be drop mounted 

from a ceiling.

 

OPTIONAL DELUXE 90° SWIVEL MOUNT

Backplate

Deluxe 

90° Swivel 

Bracket

Locking

Disc

Figure 8. Optional 106-169 Deluxe 90° 

Swivel Bracket

Отзывы: