SMARTLINK LUX–TWR RADIO PIR MANUAL
PAGE 3
FUNCTIONAL 'SYSTEM' TESTING
A system test should be done by physically walking
across the LUX–TWR coverage pattern while the system
is fully armed. NOTE: Allow time for the Sleep Cycle
Timer to expire before testing. Always notify the Cen-
tral Monitoring Station prior to performing any testing.
WALK TEST
Walk test is a way to verify that the sensor is operating
as desired and in the optimum location. Slow and short
steps should be taken across the coverage zones in
both directions. When motion is detected, the White
LeD should blink once followed by a quick blink of the
green RF ACK LeD. The green LeD indicate that the
sensor transmitted an alarm signal an that the control/
transceiver acknowledged that transmission. See
paragraph titled: RF ACKnowledge LED
NOTE: Walk Test mode bypasses the Sleep Cycle timer
allowing the Sec./Convenience LeD and the RF ACK
LED to operate regardless of DIP switches 2, 3, and 4.
SeNSOR WALK TeST
This is started by opening and closing the sensor
housing to violate the tamper switch. Sensor Walk
Test will end after 10 minutes.
RF ACKnowledge (Green) LED
This LeD is located in the clear lens on the sensor front.
It's a bi-Colour LeD providing visual status of the two-way
acknowledge (response) from the control/transceiver.
In bright lighting conditions this LED may be difficult
to see. DIP Switch #2 allows the green LeD to be
disabled for all operations except the Walk Test Mode.
GREEN blink =
Sensor has successfully transmitted a
violation (alarm) transmission to the transceiver and
that signal has been received and acknowledged by
the transceiver. The green blink is not provided for
a sensor restore transmission..
ORG/RED blink =
Sensor was not successful in trans-
mitting after multiple attempts.
DISABLING RF ACKnowledge (Green) LED
DIP Switch #2 allows the RF ACKnowledge (green)
LeD to be disabled for regular operation, helping pre-
vent unauthorized persons from learning the coverage
patterns. It also helps extend battery life. Place DIP
Switch #2 in the "NO" position to disable the RF ACK
LED, or in the "YES" position to enable the RF ACK LED.
NOTES: DIP Switch #2 does not disable this LED from
working in the Walk Test Mode.
Creep Zone
"Lookdown"
Security/
Convenience
LED (White)
RF ACK
Bi-Colour LED
(Green + Org/Red)
Figure 6. Front View of Sensor
COVERAGE PATTERNS
Figure 1. Top and Side Views
(assumes range is set to "HI")
2.1m
0.3m
1m
3m
6m
15m
6. After enrolling the sensor into the control and setting
the Option Switches, reposition sensor over the
back housing and snap it into place. This action
will activate the Walk Test mode for the next 10
minutes. Perform an immediate Walk Test accord-
ing to the procedure that follows.
7. If the swivel mount bracket was used then it will be
possible to adjust (fine tune) the Sensor coverage.
If the swivel bracket was not used, and the sensor
was fixed mounted to the wall, the coverage pattern
is based on the mounting height and position.
8. After Walk Testing has been completed, secure
the sensor to the back housing using the locking
screw provided (small countersunk screw).
PULSE COUNT (Switch 6)
Sensor must detect 1 or 2 events in the
coverage area before an alarm is created.
FUTURe (Switch 1)
Sensor must detect 3 or 4 events in the
coverage area before an alarm is created.
RANGE (Switch 5)
Sensor is set for the shorter detection range
(approximately 12m.)
Sensor is set for the longest detection range
(approximately 15m.)
To extend battery life, a mandatory sleep cycle (2 time
settings) begins after each alarm transmission. After
the Sleep Cycle expires, there must be ~8 seconds of
quiet (no movement) before the sensor will be allowed
to detect and send another radio transmission.
Long (120 secs.) Until this timer expires
the sensor cannot transmit another event.
SECURITY/CONVENIENCE LED (Switch 3)
This switch is not currently used.
Short (30 secs.) Until this timer expires
the sensor cannot transmit another event.
Sec/Convenience LED is NOT ENABLED
except for the Walk Test.
Sec/Convenience LED is ENABLED for
other functions other than Walk Test and
audible alarms. See back page for details.
RF ACK LeD (Switch 2)
RF ACK (Green) LED is NOT ENABLED
except during the Walk Test Mode.
RF ACK (Green) LED is ENABLED, and
should blink green upon a detect and
positive acknowledgment from the control.
SLEEP CYCLE (Switch 4)
5.
DIP SWITCH OPTION SETTINGS
Green = Sensor transmitted and received a positive
ACK (acknowledgment) from the Control/
Transceiver.
Org/Red = Sensor attempted to transmit but did not
receive an ACK (acknowledgment) from the
Control/Transceiver.
Figure 7. DIP Switches
1 - 2
HI
SH
YES
NO
N/A
3 - 4
LO
LG
NO
YES
N/A
PuLSE COuNt
RANGE
SLEEP CYCLE
SEC/CONv. LED
RF ACK. LED
FutuRE uSE
*Factory default, all off
ON
OFF*
1 - 2
HI
SH
YES
NO
3 - 4
LO
LG
NO
YES
N/A
ANTI-TAMPER SWITCH
This switch detects the separation of the front housing
from the backplate, resulting in a signal being transmitted
to the control/transceiver that will cause the associated
zone to become violated. Snapping the front housing
back onto the backplate will transmit a restoral.
A deluxe 90° swivel bracket may be purchased and
used in lieu of the standard swivel bracket. This bracket
has a short extended arm and allows the sensor to be
aimed at up to a 90° offset from the wall or base. This
bracket also allows the sensor to be drop mounted
from a ceiling.
OPTIONAL DELUXE 90° SWIVEL MOUNT
Backplate
Deluxe
90° Swivel
Bracket
Locking
Disc
Figure 8. Optional 106-169 Deluxe 90°
Swivel Bracket