background image

Factory Reset (to default settings)

The factory reset procedure can be used to clear the LampLinc’s memory and
restore its factory default settings. This procedure will clear the unit of all scene
addresses and fade-on/off rates. 

1.

Unplug the LampLinc

from the receptacle for about 10 seconds.

2. While 

holding down the set button

on the lower right-hand side, 

plug it back in.

3. After plugging the module back in, 

continue to hold

down the set button for

about 

2 or 3 more seconds

.

4.

Release

the set button, the Green Status LED will remain on and the load

(lights controlled by the LampLinc) will be off. 

5. After 30 seconds, the lamp's light will come on to full brightness. This indicates

that the factory reset is complete. The module is now reset to all the default set-

tings, responds to primary address A-1, and is ready for programming or use.

LampLinc

Essential 

2000SC

LampLinc

PLC

2000SHL

LampLinc

Plus

2000SLS

LampLinc

2-Way

2000STW

Regular

Lamp

Modules

Max

Watts

300

400

400

400

300

Scene

Lighting

No

No

Yes - 64

Yes - 64

No

2-Way

Transmit

No

No

No

Yes 

No

Signal Collision

Avoidance

N/A

N/A

N/A

Yes 

N/A

Load

Monitoring

No

No

No

Yes

No

Local

Control

Yes

Yes

Yes

Yes 

Yes

Local Control

easily disabled

No

Yes

Yes

Yes 

No

LED Status

Indicator

No

Yes

Yes

Yes 

No

Address

Electronically set

Yes

Yes

Yes

Yes 

No

Fades

on & off

No

Yes

Yes

Yes 

No

Responds to

PRESET Dim

Commands

No

Yes

Yes

Yes 

No

Ramp Rate

Adjustable

No

Yes

Yes

Yes 

No

Resume

Dim

Yes

Yes

Yes

Yes 

No

Low Signal

Absorption

Yes

Yes

Yes

No 

Yes

Warranty

2-Years

2-Years

2-Years

2-Years

1-Year

Lamp Module Comparison Chart

8

LampLink Plus& PLC for web (Mar04).qxd  3/15/2004  9:59 AM  Page 8

Содержание LampLinc Plus 2000SLS

Страница 1: ...LampLincTM Intelligent lamp modules packed with features For models 2000SLS LampLinc Plus 2000SLS3 LampLinc Plus with ground pin 2000SHL LampLinc PLC 2000SHL3 LampLinc PLC with ground pin ...

Страница 2: ...0 watts Responds to 65 different X10 PLC PowerLine Carrier signals Plus models only 32 levels of dimming and 32 fading on off rates No tools or hardwiring into the electrical system Pass through receptacle on the front for other un controlled electrical devices Green Status LED indicator shows powerline activity Codes are electronically set no code wheels and remembered even if unplugged Two year ...

Страница 3: ...2 Send the X10 PLC signal from any transmitter within 30 seconds 3 Send an ON to enable local control OR 4 Send an OFF to disable local control see page 4 for more detailed instructions Setting the Fade On Off Rate 1 Turn on the lamp 2 Seconds 2 Adjust the dim level Brighter faster dimming 3 Double tap the Set Button press it TWICE quickly see page 4 for more detailed instructions Setting the On D...

Страница 4: ...een Status LED will stop flashing Controlling the Lamp Remotely The LampLinc responds to any of the 256 PLC X10 addresses The LampLinc will respond to ON OFF ALL LIGHTS ON ALL UNITS OFF PRESET DIM BRIGHT and DIM commands The LampLinc can be controlled remotely from any compatible transmitter by sending its base address e g M6 and the command Setting the Fade On Off Rate Optional The Fade On Off is...

Страница 5: ...ault On Level can be remotely set using a ControLinc Duo Smarthome 4071 a Maxi Controller 4020 or an equivalent transmitter capable of sending Housecode and Unit Code without ON or OFF These procedures and all the following ones will not work with a transmitter that sends the address with a command Transmitters in which one button is pressed to turn on or off a load will not work Remotely Setting ...

Страница 6: ... Smarthome products SwitchLinc 2 Way and Plus Dimmers SwitchLinc RX Plus Dimmers KeypadLincTM with Integrated Dimmer SwitchLinc 2 Way Switches ToggleLincTM 2 Way and Plus Dimmers SwitchLinc Timer ApplianceLincTM 2 Way Plus Modules SwitchLinc Relay 2 Way The scenes for all these modules can be setup simultaneously using the same pro gramming sequence Signals sent by transmit enabled Smarthome produ...

Страница 7: ...new Fade On Off Rate has been set Other Options All LampLinc models only Disable Programming Once the LampLinc is set up it can be programmed to lockout any changes Any changes made at the module by pressing the Set Button or remotely will be ignored Please note that all LampLinc and SwitchLinc that are plugged in or electri cally active will be locked out 1 Send the following command sequence to ...

Страница 8: ...t the factory reset is complete The module is now reset to all the default set tings responds to primary address A 1 and is ready for programming or use LampLinc Essential 2000SC LampLinc PLC 2000SHL LampLinc Plus 2000SLS LampLinc 2 Way 2000STW Regular Lamp Modules Max Watts 300 400 400 400 300 Scene Lighting No No Yes 64 Yes 64 No 2 Way Transmit No No No Yes No Signal Collision Avoidance N A N A ...

Страница 9: ...t of a duplex wall receptacle if plugged into the top outlet If possible use the bottom outlet for the lamp module so that the other outlet is accessible for other use For convenience a pass through receptacle has been supplied on the lamp module so you don t lose a receptacle If the LampLinc is plugged into a receptacle controlled by a wall switch consider leaving the switch on at all times This ...

Страница 10: ... in my North American wall outlet Problem Solution Check scene membership and remove any unwanted scenes from LampLinc or perform a Factory Reset to clear it Install an PLC Signal Blocker in the home to keep PLC signals from neighboring homes from interfering Set a new fade on rate Increase brightness press set button twice Re set the primary address by sending the house and unit code fol lowed by...

Страница 11: ... design power supplies build in traps to filter out and kill electrical noise Unfortunately the PLC signals looks like electrical noise to these devices The result is that a large percent of the transmitted signal is lost to these devices leaving less for the receivers The most common sources of signal loss are Televisions Computer systems Audio Video gear Computer UPS s and power strips Power sup...

Страница 12: ... of Seller s liability with respect to this product For repair or replacement during the warranty period call Smarthome customer service to receive an RA return authorization number properly package the product with the RA clearly printed on the outside of the package and send the product along with all other required materials to Smarthome Inc ATTN Receiving Dept 16542 Millikan Ave Irvine CA 9260...

Отзывы: