Longo programmable controller LPC-2.DO4
Written by SMARTEH d.o.o.Copyright © 2005, SMARTEH d.o.o.
User Manual
Document Version: 6June, 2019
i
Страница 1: ...USER MANUAL Longo programmable controller LPC 2 DO4 Triac Output module Version 6 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si...
Страница 2: ...Longo programmable controller LPC 2 DO4 Written by SMARTEH d o o Copyright 2005 SMARTEH d o o User Manual Document Version 6 June 2019 i...
Страница 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...
Страница 4: ...r LPC 2 DO4 Longo programmable controller LPC 2 DO4 1 DESCRIPTION 1 2 FEATURES 2 3 INSTALLATION 3 3 1 Connection scheme 3 3 2 Mounting instructions 5 3 3 Module labeling 7 4 TECHNICAL SPECIFICATIONS 8...
Страница 5: ...ut module It can be used in a wide range of operation LED indicates triac output contacts state If it is on the module s connection pins are shorted refer to the Table 5 Module is powered from interna...
Страница 6: ...DO4 2 FEATURES Figure 1 LPC 2 DO4 module Table 1 Technical data Snubberless zero crossing triac output also suitable for use with inductive loads Long life AC digital output Small dimensions and stan...
Страница 7: ...tput 24 230 V AC Make contact triac output NO Table 3 K1 Internal BUS Data DC power supply Connection to I O module Table 4 K2 Internal BUS Data DC power supply Connection to I O module 1 Wires connec...
Страница 8: ...tal output state On triac on conductive Off triac off non conductive NOTE Special care must be taken in case of high inductance loads e g Relays or contactors High inductance load may cause output fai...
Страница 9: ...MMENDATION ON SWITCH OR CIRCUIT BREAKER PROTECTION There should be two poles main switch in the installation in order to switch off the unit The switch should meet the requirements of standard IEC6094...
Страница 10: ...scheme in Figure 2 5 Switch ON main power supply Dismount in reverse order For mounting dismounting modules to from DIN rail a free space of at least one module must be left on the DIN rail NOTE LPC 2...
Страница 11: ...e code 04 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 descriptio...
Страница 12: ...triac make contacts NO Output current 0 05 1 8 A continuous load Connection type screw type connector for stranded wire 0 75 to 2 5 mm2 Dimensions L x W x H 90 x 18 x 60 mm Weight 50 g Ambient tempera...
Страница 13: ...following table describes all the changes to the document Date V Description 14 6 2019 6 Additional note added 1 7 2012 5 CGP General update 11 5 2010 4 Updated warranty permanence 30 6 2005 3 The in...
Страница 14: ...Longo programmable controller LPC 2 DO4 6 NOTES 10...