background image

Longo programmable controller LPC-2.CH1 special module

2 FEATURES

Figure 1: LPC-2.CH1 special module

Table 1: Technical data

RFID reader

RFID card slot

Adjustable LED intensity

LEDs for showing activated messages & requests: do not disturb, room service

2 touch buttons for activating messages & requests: do not disturb, room service

OK “ 

√ 

” LED

FAULT “ X ” LED

Power LED

Internal fault LED

Internal built-in buzzer

2

Содержание LPC-2.CH1

Страница 1: ...USER MANUAL Longo programmable controller LPC 2 CH1 special module Version 2 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Страница 2: ...Longo programmable controller LPC 2 CH1 special module Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User Manual Document Version 002 July 1 2012 i...

Страница 3: ...e to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual...

Страница 4: ...ontroller LPC 2 CH1 special module 1 DESCRIPTION 1 2 FEATURES 2 3 OPERATION 3 3 1 Parameters 3 4 INSTALLATION 4 4 1 Connection scheme 4 4 2 Mounting frame selection 6 4 3 Mounting instructions 7 4 4 M...

Страница 5: ...to the room the key card should be inserted to the CH1 card slot If card ID for correspondent room is valid several actions can be started e g room light and air conditioning switched on CH1 module fe...

Страница 6: ...Table 1 Technical data RFID reader RFID card slot Adjustable LED intensity LEDs for showing activated messages requests do not disturb room service 2 touch buttons for activating messages requests do...

Страница 7: ...bled or cleared Parameter can be status or command Parameter as status means that CH1 module is sending information to MCU On the other hand command represents request from MCU to module iComm Normal...

Страница 8: ...Longo programmable controller LPC 2 CH1 special module 4 INSTALLATION 4 1 Connection scheme Figure 2 Connection scheme 4...

Страница 9: ...st LED3 red FAULT X On RFID key standard NOK or ID card number wrong Off No tag in proximity LED4 green OK On RFID key standard OK and ID card number valid Off No tag in proximity LED5 red Communicati...

Страница 10: ...CH1 module Bticino Living Light Gewiss Playbus System Vimar Plana Idea Tem Modul Soft Modul Line Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Befor...

Страница 11: ...to the main power supply Module should not be mounted outdoors Several RFID panels should not be mounted close to each other Minimum distance to next panel is at least 30 cm This restriction also app...

Страница 12: ...cover plate LPC 2 CH1 connects to the MCU unit on its RS485 port using interconnection cable When more special modules e g LPC 2 CR1 LPC 2 CH1 LPC 2 DP1 are connected to MCU splitter is also required...

Страница 13: ...es flush frame mounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades D C 10 10 is the date code 01 week and 10 year of production S N CH1 S9 1000000003...

Страница 14: ...2 6 6 Power consumption 2W RFID type EM4100 125kHz Manchester 64 read only Max reading distance RFID card inserted into CH1 slot Dimensions W x H x D 75 x 49 x 29 mm Weight 40 g Ambient temperature 0...

Страница 15: ...ler LPC 2 CH1 special module 6 CHANGES The following table describes all the changes to the document Date V Description 1 1 2012 002 CGP General update 1 10 2010 001 The initial version issued as LPC...

Страница 16: ...Longo programmable controller LPC 2 CH1 special module 7 NOTES 12...

Отзывы: