Longo programmable controller LPC-2.C06

Written by SMARTEH d.o.o.
Copyright © 2020, SMARTEH d.o.o.

User Manual

Document Version: 1
June, 2020

i

Содержание LPC-2.C06

Страница 1: ...USER MANUAL Longo programmable controller LPC 2 C06 Communication terminal Version 1 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si ...

Страница 2: ...Longo programmable controller LPC 2 C06 Written by SMARTEH d o o Copyright 2020 SMARTEH d o o User Manual Document Version 1 June 2020 i ...

Страница 3: ...not include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVI...

Страница 4: ...mable controller LPC 2 C06 1 ABBREVIATIONS 1 2 DESCRIPTION 2 3 FEATURES 3 4 OPERATION 4 4 1 Parameters 4 5 INSTALLATION 7 5 1 Connection scheme 7 5 2 Mounting instructions 9 5 3 Module labeling 11 6 TECHNICAL SPECIFICATIONS 12 7 CHANGES 13 8 NOTES 14 iii ...

Страница 5: ...Longo programmable controller LPC 2 C06 1 ABBREVIATIONS DC Direct Current TTL Transistor Transistor Logic RX Receive TX Transmit UART Universal Asynchronous Receiver Transmitter 1 ...

Страница 6: ... being a gateway for UART protocols exchanging UART data with the main module where all of data is being interpreted That way different communication protocols which are based on the RS 232 TTL or RS 485 UART protocols can be implemented e g DMX proprietary protocols LPC 2 C06 is controlled and powered from the main module e g LPC 2 MC9 via Right internal bus 2 ...

Страница 7: ...ATURES Figure 1 LPC 2 C06 module Table 1 Technical data RS 232 port with possibility to use TTL voltage levels select able with jumper RS 485 port Signal LEDs Supplied from main module Small dimensions and standard DIN EN50022 35 rail mounting 3 ...

Страница 8: ...e USINT Raw to engineering data 0 255 0 255 Received data length Rx_Data_Len Number of data in Rx Buffer Type UINT Raw to engineering data 0 65535 0 65535 Received telegram status Rx_TLG_Status Status of received telegram Type USINT Raw to engineering data xxxxxxx0 No telegram timeout xxxxxxx1 Telegram timeout Xxxxxx0x No data byte timeout xxxxxx1x Data byte timeout xxxxx0xx No parity error xxxxx1...

Страница 9: ...l is used Protocol option Protocol_Option Protocol options Type USINT Raw to engineering data xxxxxxx0 RS485 xxxxxxx1 RS232 Xxxxxx0x Normal TTL Tx signal xxxxxx1x Inverted TTL Tx signal xxxxx0xx Normal RS232 and inverted TTL Rx signal xxxxx1xx Inverted RS232 and normal TTL Rx signal UART speed UART_Speed Selector of baudrate Type USINT Raw to engineering data 0 300 1 600 2 1200 3 2400 4 4800 5 960...

Страница 10: ...ata Type UINT Raw to engineering data 0 No timeout other Timeout value in us Received data length Rx_Data_Len Length of received data Type UINT Raw to engineering data 0 1000 Number of expected data 1001 AUTO receive data until timeout or buffer is full other AUTO Transmitted data length Tx_Data_Len Number of bytes to transmit Type UINT Raw to engineering data 0 270 0 270 bytes Transmit counter Tx...

Страница 11: ...vels RS485 6 RS 485 B Table 3 RS2321 RS232 1 GND RS232 2 RS 232 Tx S1 Position 1 2 RS232 RS 232 standard voltage levels S1 Position 2 3 TTL 0 5 V RS232 3 RS 232 Rx Table 4 K1 Internal BUS Data DC power supply Connection to I O module 1 Wires connected to the module must have cross sectional area at least 0 75 mm2 Minimum temperature rating of wire insulation must be 85 C 7 ...

Страница 12: ...Longo programmable controller LPC 2 C06 Table 5 K2 Internal BUS Data DC power supply Connection to I O module Table 6 S1 Voltage levels for RS232 port S1 Position 1 2 RS 232 S1 Position 2 3 TTL 8 ...

Страница 13: ...equired Mount each module to the DIN rail first then attach modules together through K1 and K2 connectors 4 Connect input and output wires according to the connection scheme in Figure 2 5 Switch ON main power supply Dismount in reverse order For mounting dismounting modules to from DIN rail a free space of at least one module must be left on the DIN rail NOTE LPC 2 main module should be powered se...

Страница 14: ...Longo programmable controller LPC 2 C06 Figure 4 Minimum clearances The clearances above must be considered before module mounting 10 ...

Страница 15: ...uct name CCDDD sequence code CC year of code opening DDD derivation code EEE version code reserved for future HW and or SW firmware upgrades 3 S N SSS RR YYXXXXXXXXX serial number SSS short product name RR user code test procedure e g Smarteh person xxx YY year XXXXXXXXX current stack number 4 D C WW YY date code WW week and YY year of production Optional 1 MAC 2 Symbols 3 WAMP 4 Other 11 XXX N ZZ...

Страница 16: ...e screw type connector for stranded wire 0 75 to 1 5 mm2 Dimensions L x W x H 90 x 18 x 60 mm Weight 60 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position vertical Transport and storage temperature 20 to 60 C Pollution degree 2 Overvoltage category II Electrical equipment Class II double insulation Protection class IP 30 12 ...

Страница 17: ...ongo programmable controller LPC 2 C06 7 CHANGES The following table describes all the changes to the document Date V Description 12 06 2020 1 The initial version issued as LPC 2 C06 module UserManual 13 ...