background image

 

120621-XE3243EO-0831-V2.1-V2a 

1.6 Camera Overview 

1.  Switches & Connectors 

       

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

■ DI / DO Port: 

(1)

 

IO

 

(2)

 

IO

 

(3)

 

ALM-RST (Alarm Reset): 

The system will force the alarm input to cancel. 

(4)

 

ALM-IN (Alarm Input):

 When activate, the alarm input will be triggered.   

(You may also set the alarm to input while the DAY/NIGHT Mode is activated.) 

(5)

 

ALM-OUT (Alarm Output):

 When activate, the alarm output will be triggered.   

(You may also set the alarm to output while the DAY/NIGHT Mode is activated.) 

(6)

 

GND (Ground)

   

(7)

 

RS-485(

) Output:

 Controlled by RS-485 signal sent by the network part (NEGATIVE) 

(8)

 

RS-485(

) Input:

 Controlled by RS-485 signal sent by the network part (POSTIVE) 

 
■Heater: 

This heater will keep the lens and glass free of obscuring condensation. The built-in thermostat 
switches the heater on and off appropriately. 

 
 
 

Audio Out 

Reset Switch 

LAN / PoE (RJ-45) 

Power 12V DC 

Heater 

Audio In 

DI / DO 

Video Out 

Содержание STC-IPM3542A/1

Страница 1: ...1 3 Megapixel WDR IP Camera STC IPM3542A 1 Thanks for purchasing our product Before operating the unit please read the instructions carefully and keep this manual for future reference...

Страница 2: ...era toward the sun Direct sunlight or severe ray may cause fatal damage to sensor and internal circuit 6 Power Cord Protection Touching the wet power cord with hands or touching the power cord with we...

Страница 3: ...ts smoke or abnormal heat 13 Servicing Do not attempt to repair this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified s...

Страница 4: ...ENTS 1 1 3 SYSTEM REQUIREMENTS 1 1 4 SPECIFICATION 2 1 5 DIMENSIONS 3 1 6 CAMERA OVERVIEW 4 1 7 INSTALLATION 5 2 USER INTERFACE 7 2 1 LOGIN 7 2 2 INTERFACE OVERVIEW 8 1 Live View 9 2 Video 10 3 Image...

Страница 5: ...080p 2056x1536p 3 0MP Suggested Bitrate 2000 4000kbps 2000 6000kbps 4000 8000kbps 4000 10000kbps Compression format H264 or MPEG4 H264 or MPEG4 H264 or MPEG4 H264 or MPEG4 Frame Rate Up to 30fps Up to...

Страница 6: ...Motion Detection Yes Motion Alarm Trigger Yes Timer Clock Yes Camera Control Interface Pelco D Pelco P Customer NETWORK Browser IE 8 0 or Above Ethernet 10 100M Auto Negotiation Bit Rate Transmission...

Страница 7: ...120621 XE3243EO 0831 V2 1 V2a 3 1 5 Dimensions...

Страница 8: ...tput When activate the alarm output will be triggered You may also set the alarm to output while the DAY NIGHT Mode is activated 6 GND Ground 7 RS 485 Output Controlled by RS 485 signal sent by the ne...

Страница 9: ...teway 192 168 1 1 START Power Type FINISH DC Check the power of PoE Plug the Power Adapter Connect the RJ 45 LAN cable to the IP CAM Get into the IP CAM setting window PoE IP setting for PC NB Please...

Страница 10: ...ssword 4 Whenever the connection is ready the main page setting window of IP CAM will show on 3 Link via Hub PoE Hub Make sure PC installed with JAVA Version 6 Update 30 or above 1 Run the IE browser...

Страница 11: ...ut http 192 168 1 168 in the address field then press Enter 2 Enter User Name and Password In the prompt window and click OK The default User Name and Password is admin and 9999 You will need to enter...

Страница 12: ...em the screen will be displayed as below There are many function buttons on the left side They are as the table below All of the function buttons and its details will be shown on the following section...

Страница 13: ...page Display the image captured by the camera Language English Japanese Traditional Chinese Simplified Chinese Vary by area Full Screen Snapshot Record Save Stop Recording Information Motion Detect Up...

Страница 14: ...tings of IP stream type streams and local display NOTE Once the change completed click Submit to save the settings Stream Type Video Streams Single Dual Tri stream Codec Profiles H 264 MPEG4 MegaPixel...

Страница 15: ...5 sec 10 sec Shutter Speed Min Second 1 2 1 4 1 8 1 15 1 30 1 60 1 120 1 250 1 500 1 750 1 1000 1 1500 1 2000 1 10000 1 100000 Shutter Speed Max Second 1 30 1 60 1 120 1 250 1 500 1 750 1 1000 1 1500...

Страница 16: ...Image Brightness 0 255 Default 128 Contrast 0 255 Default 128 Saturation 0 255 Default 128 Sharpness 0 255 Default 128 DeNoise 0 255 Default 128 EV Compensation 0 255 Default 128 Load Default Restore...

Страница 17: ...licker Control 60hz NTSC 50hz PAL White Balance AUTO_WIDE AUTO_NORMAL SUNNY SHADOW INDOOR LAMP FL1 FL2 Back Light Compensation Off On Back Light Level Min Mid Max WDR Enhancement Off On WDR Level 0 7...

Страница 18: ...V2a 14 4 Audio Modify the settings of audio Audio Enable Audio Enable Disable Audio Mode MIC SPEAKER BOTH Input volume 0 100 Sample Rate 8KHz 16KHz Bitrate Auto 64Kbps Output Volume 0 100 NOTE The co...

Страница 19: ...l Date Manual set the date and time Sync Current PC Date Synchronization the date and time with current PC Sync with SNTP Server Synchronization the date and time with SNTP Server Date Format Position...

Страница 20: ...nnection Multicast Enable Multicast Enable Disable H264 Main Sub Port Communication port for H 264 MPEG4 Main Sub Port Communication port for MPEG4 MJPEG Port Communication port for M JPEG SMTP SMTP A...

Страница 21: ...Level Alarm level of DI DO Alarm Trigger Motion Motion trigger alarm None support for single M JPEG Ethernet Loss Trigger alarm if Ethernet loss DI1 DO1 Mode Trigger modes for DI DO Alarm Action Uplo...

Страница 22: ...1 V2 1 V2a 18 8 Storage Modify the settings of storage and files upload Storage Upload via FTP File format for upload via FTP Local Storage Save File format for save files Schedule Scheduling the stor...

Страница 23: ...f the firmware Mac Address Mac address assigned by production Firmware Update Update the firmware IP CAM Restart Reboot this IP camera Name Password Change the login User Name and Password Authority C...

Страница 24: ...Pelco D and Pelco P Use protocols other than Pelco D and Pelco P define the commands in the field of Customer General ID 0 255 Baud 1200 2400 4800 9600 19200 38400 57600 115200 Pelco D Pelco P Zoom 0...