TEST PROCEDURE HRD TEST
1. Turn on machine.
2. Keep PLT/HRD switch on “HRD”.
3. Keep SET/RUN switch on “SET”.
4. Set required Test Current (Amperes).
5. Set Cutoff Voltage for test.
6. For “HRD” test no need to set timer.
7. Keep SET/RUN switch on RUN mode.
8. Connect Battery Under Test.
9. Machine will show test current,
battery volatge and zero timer.
CURRENT
VOLTAGE
TIMER
CURRENT
VOLTAGE
TIMER
CURRENT
VOLTAGE
TIMER
CURRENT
VOLTAGE
TIMER
10. Now Press START button or
foot switch (if provided) to start test.
11. Machine will put a load of a shown
test current and timer will start.
12. During test machine shows Green
and Red indication alternately.
CURRENT
VOLTAGE
TIMER
CURRENT
VOLTAGE
TIMER
CURRENT
VOLTAGE
TIMER
13. Test will end when battery voltage
drops below Cutoff.
15. After test end, LED blinking will stop,
and the time value is final HRD test timing.
CURRENT
VOLTAGE
TIMER
14.If HRD test continues for duration greater
than 59:59 minutes, HH:MM led is ON
and timer will show time in HH:MM.
CURRENT
VOLTAGE
TIMER
HH:MM led is ON
Time is 1 hour 36 Min
CURRENT
VOLTAGE
TIMER
For HRD test, timer setting is not considered
Timer will always start counting up from Zero.
Содержание PLT600