A P P E N D I X B
Remotely managing your system through an RS-232 serial interface
76
smarttech.com/kb/170549
Field
Possible Values
Description
current colorwheelidx
???
The ranges must match the OSD ranges.
current failurelog
l
normal
l
overtemp
l
fanlock
l
fanDMD
l
fanblower
l
fansystem
l
lamperror
l
colorwheelbreak
l
lampignite
l
lampoverheat
l
lampdriver
l
lampoverhours
Projector's error state. The modes are projector
dependent.
Current error#
Provide the details of
the specific error. “#” is
the number recorded in
the log. It ranges from 1
to 5. 1 indicates the
most recent error and 5
indicates the oldest
error.
The details include the failure reason, system
hours, lamp hours, sensor temperature and lamp
voltage.
Example: error1=fansystem, syshrs:1000,
lamphrs=1000, temp=60,volt=120.
error2=lampoverheat, syshrs:3000,
lamphrs=2900, temp=150,volt=120.
target factoryreset
l
= true
l
= false
If set to “true,” perform a factory reset.
Otherwise, do nothing.
current factoryreset
l
= true
l
= false
Set to “true” only if a factory reset is about to
occur.
target highspeedfan
l
= high
l
= normal
Must match the OSD settings.
current highspeedfan
l
high
l
normal
Must match the OSD settings.
current statereporting
l
on
l
off
Current state reporting value
target statereporting
l
= on
l
= off
Target state reporting value