Before Installation

1). Read the instructions carefully.
2)   Make sure the door structure is solid and suitable to 

be motor driven.

3)   Make sure that when the door is moving there are no 

friction points.

4)   The door must be properly balanced and must be 

easily lowered and raised by hand.

5)   A 240V, adequately protected 3-pin socket must be 

near where the Smart Roller Duo opener is going to 

be installed.

Remember

 there are specific standards that have to 

be strictly followed regarding the safety of electrical 

installations and automatic gates and doors.
As well as the legal requirements and standards that 

must be adhered to, please take note of the following 

points to ensure maximum safety and reliability of your 

installation.
6)   Prior to installing check the surrounding environment. 

Carefully evaluate any hazards there could be from 

physical damage (transiting vehicles, parts of trees 

falling etc.), possible contact with foreign bodies 

(insects, leaves, etc.), flooding hazards or any others 

exceptional events.

7)   Check that the main voltage is the same as that given 

on the rating plate and in this manual.

8)   Check there is suitable electrical protection against 

short circuits/power spikes and proper earthing on the 

main supply.

Remember

 the unit has mains voltage running through it 

(electrocution hazard, fire hazard).

9)   Take care with the control unit; parts may be subject 

to damage if abused.

10)  Make sure you have all the necessary materials and 

that they are suitable for this kind of use.

11)  Read all the instructions thoroughly and make sure 

they are understood before attempting to install the 

Smart Roller Duo.

12)  Before starting the installation, carefully analyse all 

the risks relating to automating the door. Verify that 

the door to be automated is in a sound condition 

and that the mechanisms are in good working order; 

observe the safety margins and minimum distances.

13)  Evaluate with particular care the safety devices to be 

installed and where to install them; always install an 

emergency stop device for interruption of power to the 

opener if required.

14)  Once the risks have been analysed, install the Smart 

Roller Duo opener and relative safety devices, 

emergency stop and/or photoelectric cells.

Important: 

For additional safety Smart Openers Pty Ltd 

strongly recommends the fitting of Photo Electric safety 

beams on all installations.
15)  When installing the Smart Roller Duo opener, strictly 

follow all the instructions given in the instruction 

manual. If some points or procedures in this manual 

are not very clear do not install the unit until all doubts 

have been cleared up with our technical department.

Important: 

Make sure that the motor wires have been 

connected to the wiring harness correctly.
They should be: 

   

 

   Red – Red

   

 

Green – Yellow

If this is not the case please swap the connection to the 

above polarity before proceeding.

Red
Red

Green
Yellow

Содержание SMART ROLLER DUO

Страница 1: ... INSTALLING AND USING THIS OPENER TO FOLLOW THE INSTALLATION INSTRUCTIONS AND SAFETY WARNINGS FAILURE TO COMPLY MAY RESULT IN SERIOUS PERSONAL INJURY AND OR PROPERTY DAMAGE AND FAILURE OF THE OPENER SYSTEM INSTALLATION MANUAL SMART ROLLER DU ROLL UP DOOR OPENER duo ...

Страница 2: ... be lawfully excluded Smart Openers Pty Ltd hereby expressly excludes all conditions and warranties statutory or otherwise which may be implied by law as conditions or warranties of purchase of a Smart Openers Pty Ltd Garage Door Opener Smart Openers Pty Ltd hereby further disclaims and rejects to the maximum extent permitted by law any liability or responsibility whatsoever for any direct indirec...

Страница 3: ... expense or claim whatsoever suffered by any person as a result whether directly or indirectly from failure to install the system correctly and in accordance with the relevant safety standards and installation manual For a more detailed list of the Safety Warnings and Safety Issues associated with the installation and use of a Smart Roller Duo roll up door opener refer to the safety warnings in th...

Страница 4: ... 4 Operating Controls MIN Lrn Run Prog MAX 24V GND PE PE DIP GND PB 6 7 8 1 2 3 4 10 9 5 11 12 6 13 15 16 17 18 19 20 7 8 1 2 3 4 WHT BWN GRN RED YLW ...

Страница 5: ... auto close function 1 min set close time 8 Right Hand Left Hand Dipswitch used during installation Dipswitch is factory preset for RH for LH installation set dipswitch up 9 24 Volt AC Input 5 10 24 Volt Battery Input 11 Learn Button used to store transmitter into memory 12 Learn LED indicates learn operate mode of transmitter 13 Fuse main fuse 240V 3A 14 LED Light 15 Operate Button Open Stop Clos...

Страница 6: ...h the control unit parts may be subject to damage if abused 10 Make sure you have all the necessary materials and that they are suitable for this kind of use 11 Read all the instructions thoroughly and make sure they are understood before attempting to install the Smart Roller Duo 12 Before starting the installation carefully analyse all the risks relating to automating the door Verify that the do...

Страница 7: ...ight Hand Installation The Smart Roller Duo is shipped from the factory ready for installation on the RIGHT SIDE of the door when viewed from inside the garage If you are installing this opener on the RIGHT SIDE then proceed to the next step If installing on the LEFT SIDE then the dip switch No 1 must be shifted up as per Fig 4 Fixing The Door Curtain To Drum Wheel The door curtain has to be secur...

Страница 8: ...he right hand door bracket from the wall 6 Hold the drive unit assembly and try to rotate the drive gear by pushing the fork If it does not turn switch the opener into manual mode by pulling the red cord downwards 7 Slide the drive unit over the door shaft and make sure that the fork engages one of the spokes of the door drum wheel 8 Refit the door bracket to the wall In some cases it may need to b...

Страница 9: ...gage the drive unit by pulling the red cord see Fig 14 Open Limit Adjustment 1 Press the Operate Button on the Control Box The door should start moving 2 If the door stops at the desired open limit position then the limit adjustment is complete 3 If the door has not reached or has gone past the desired position adjust the UP LIMIT CAM clockwise to open the door more or to open the door less adjust...

Страница 10: ... unit by pulling the red cord see Fig 14 Open Limit Adjustment 1 Press the Operate Button on the Control Box The door should start moving 2 If the door stops at the desired open position then the limit adjustment is complete 3 If the door has not reached the desired position adjust the UP LIMIT CAM anticlockwise to open the door more or to open the door less adjust the cam clockwise Close Limit Ad...

Страница 11: ... the door is closing turn the DOWN FORCE shaft slowly anticlockwise until the door stops momentarily then reverses to the open position 4 Turn the DOWN FORCE shaft 10 degrees clockwise 5 Press the Operate Button again to close the door If the door reverses by itself re adjust the DOWN FORCE shaft a further 5 degrees clockwise Keep adjusting in this manner until the door can complete the full close...

Страница 12: ... deleted transmitters It is recommended to delete all transmitters and re coding when one of the stored transmitters is lost Maintenance No particular maintenance is required for the logic circuit board At least twice a year check that the door is properly balanced and that all working parts are in good working condition IMPORTANT A poorly operating door can effect the life of the automatic opener...

Страница 13: ... a maintenance register kept by the user Information for the user is found in the USERS OWNERS MANUAL included with this opener IMPORTANT Please make sure the USERS OWNERS MANUAL is passed on to the owner prior to leaving the installation IMPORTANT In the case of a malfunction the user must call an authorized Smart Opener Pty Ltd installer and should not attempt to repair the opener Final Notes Th...

Страница 14: ...g from wear and tear c blown fuses loss or damage caused by electrical surges power surges or power spikes d loss or damage due to theft fire flood rain water lightning storms any acts of God contamination or pollution e door or gate not in safe and correct working order and condition f evidence of unauthorised repairs g any cost relating to damage caused deliberately or by misuse negligence or fail...

Страница 15: ... 15 Notes ...

Страница 16: ...uct quality and innovation smart openers reserves the right to change and alter specifications and model numbers and types without notice D N SRIM011107 Smart Openers Pty Ltd PO Box 6666 GCMC Qld 9726 Tel 1300 366 547 Fax 1300 366 972 Email enquiries smartopeners com Web www smartopeners com ...

Отзывы: