-10-
Limits Set Up
Setting Limits - LEFT HAND INSTALLATION
Note:
The RH/LH dip switch must be set to LH side.
REMINDER:
If you have not already done so, inspect
the wiring harness to confirm that the motor wires are
connected correctly: red–red and green–yellow.
1
With the Drive Unit in manual mode move the door up
by hand to the desired open position.
2
Remove the Switch Cover (see Fig 9). Rotate the UP
LIMIT CAM by hand in an anticlockwise direction until
the cam clicks the open limit switch.
3
Move the door down by hand to the desired closed
position.
4
Rotate the DOWN LIMIT CAM by hand in a clockwise
direction (see Fig 13) until the cam clicks the close
limit switch.
5
Connect power lead from the Drive Unit into a general
purpose power outlet installed by a licensed qualified
electrical contractor. Turn the power on.
6
Re-engage the drive unit by pulling the red cord.
(see Fig 14).
Open Limit Adjustment
1
Press the Operate Button on the Control Box. The
door should start moving.
2
If the door stops at the desired open position then the
limit adjustment is complete.
3
If the door has not reached the desired position,
adjust the UP LIMIT CAM anticlockwise to open the
door more or to open the door less adjust the cam
clockwise.
Close Limit Adjustment
1
Press the Operate Button on the Control Box. The
door should start closing.
2
If the door
stops at the desired closed position
then
the close limit adjustment is complete.
3
If the door has not reached the desired position,
adjust the DOWN LIMIT CAM clockwise to close the
door more or to close the door less adjust the cam
anticlockwise.
Fig. 13
Fig. 14
Fig. 12
Pull red cord to
release. Pull green cord
to engage.
Adjust cam clockwise
to open the door more
Cam rotation during
open cycle
UP LIMIT SWITCH
UP LIMIT CAM
Adjust cam anti-clockwise
to close the door more
DOWN LIMIT CAM
DOWN LIMIT SWITCH
Cam rotation during
close cycle
Содержание SMART ROLLER DUO
Страница 15: ... 15 Notes ...