![SMAR LD292 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/smar/ld292/ld292_operation-maintenance-and-instruction-manual_1294907061.webp)
Technical Characteristics
5.7
MODEL
SANITARY PRESSURE TRANSMITTERS
LD292S
F
OUNDATION
TM
fieldbus
CODE
Type Range Limits Range Limits
Min. Max. Unit Min. Max. Unit
2
3
4
5
Sanitary 12.5 500 mbar 5.02 201.09 inH
2
O
Sanitary 62.5 2500 mbar 25.13 1005,45 inH
2
O
Sanitary 0.625
25 bar 157.1 10054.5 inH
2
O
Sanitary 6.25 55.15 bar 90.65 799.89 psi
CODE
Diaphragm Material
I
316L SST
CODE
Fill Fluid
S
Silicone DC-200/20 Oil
CODE
Local Indicator
0
1
Without Indicator
With Indicator
CODE
Process Connections
B
C
D
E
F
Thread IDF -
2” 300#
(2)
Thread RJT -
2” 300#
Tri-Clamp -
2” 300#
(2)
Thread SMS -
2” 300#
(2)
Tri-Clamp -
1 1/2” 300#
(2)
H
P
Q
Z
DN40 300# - DIN 11851
Tri-Clamp -
2” 800#
(2)
Tri-Clamp -
1 1/2” 800#
(2)
User’s specifications
CODE
Electrical Connections
0
1
2
3
4
5
1/2 - 14 NPT
(3)
1/2 - 14 NPT X 3/4 NPT (316 SST) - with adapter
(4)
1/2 - 14 NPT X 3/4 BSP (316 SST) - with adapter
(8)
1/2 - 14 NPT X 1/2 BSP (316 SST) - with adapter
(8)
1/2 - 1/2 NPTF (316 SST) - with adapter
1/2 - 3/4 NPTF (316 SST) - with adapter
A
B
Z
M20 X 1.5
(5)
PG 13.5 DIN
(5)
User’s specifications
CODE
O’Ring Material
0
B
T
Without O’Ring
Buna-N
(2)
Teflon
(2)
V
Z
Viton
(2)
User´s specifications
CODE Adaptation Sleeve
0
1
Without Sleeve
With Adaptation Sleeve in 316 SST
CODE Tri-Clamp Connection
0
2
Without Clamp
With Tri-Clamp in 304 SST
CODE Diaphragm Material (Sanitary Connection)
H
I
Hastelloy C276
316L SST
CODE Fill Fluid (Sanitary Connection)
D
F
N
S
T
Z
Silicone DC-704 Oil
Fluorolube MO-10 Oil
(1)
Propilene Glicol (Neobee) Oil
(2)
Silicone DC-200/20 Oil
Syltherm 800 Oil
User’s specifications
CODE Optional Items
LD292S
2
I
N
1
D
0
V
1
2
I
D
*
←
Typical Model Number
*Leave blank for no optional items.
Содержание LD292
Страница 1: ......
Страница 2: ......
Страница 8: ...LD292 Operation and Maintenance Instruction Manual VIII...
Страница 11: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD292 Sanitary...
Страница 13: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD292 Level...
Страница 24: ...LD292 Operation and Maintenance Instruction Manual 2 4...
Страница 44: ...LD292 Operation and Maintenance Instruction Manual 3 20...
Страница 54: ...LD292 Operation and Maintenance Instruction Manual 4 10...
Страница 73: ...Appendix A A 7 CEPEL Centro de Pesquisa de Energia El trica...
Страница 74: ...LD292 Certifications Information A 8 FM Approvals...
Страница 76: ...LD292 Service Request Form B 2...