![SMAR LD292 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/smar/ld292/ld292_operation-maintenance-and-instruction-manual_1294907057.webp)
Technical Characteristics
5.3
Overpressure and
Static Pressure
Limits (MWP
–
Maximum Working
Pressure)
(continuation)
Material
Group
Pressure
Class
Maximum Temperature Allowed
-29 to
38
50
100
150
200
250
300
325
350
Maximum Pressure Allowed (bar)
AISI316L
150
15.9
15.3
13.3
12
11.2
10.5
10
9.3
8.4
300
41.4
40
34.8
31.4
29.2
27.5
26.1
25.5
25.1
400
55.2
53.4
46.4
41.9
38.9
36.6
34.8
34
33.4
600
82.7
80
69.6
62.8
58.3
54.9
52.1
51
50.1
900
124.1
120.1
104.4
94.2
87.5
82.4
78.2
76.4
75.2
1500
206.8
200.1
173.9
157
145.8
137.3
130.3
127.4
125.4
2500
344.7
333.5
289.9
261.6
243
228.9
217.2
212.3
208.9
Material
Group
Pressure
Class
Maximum Temperature Allowed
-29 to
38
50
100
150
200
250
300
325
350
Maximum Pressure Allowed (bar)
AISI316
150
19
18.4
16.2
14.8
13.7
12.1
10.2
9.3
8.4
300
49.6
48.1
42.2
38.5
35.7
33.4
31.6
30.9
30.3
400
66.2
64.2
56.3
51.3
47.6
44.5
42.2
41.2
40.4
600
99.3
96.2
84.4
77
71.3
66.8
63.2
61.8
60.7
900
148.9
144.3
126.6
115.5
107
100.1
94.9
92.7
91
1500
248.2
240.6
211
192.5
178.3
166.9
158.1
154.4
151.6
2500
413.7
400.9
351.6
320.8
297.2
278.1
263.5
257.4
252.7
Material
Group
Pressure
Class
Maximum Temperature Allowed
-29 to
38
50
100
150
200
250
300
325
350
Maximum Pressure Allowed (bar)
AISI304
150
19
18.3
15.7
14.2
13.2
12.1
10.2
9.3
8.4
300
49.6
47.8
40.9
37
34.5
32.5
30.9
30.2
29.6
600
99.3
95.6
81.7
74
69
65
61.8
60.4
59.3
1500
248.2
239.1
204.3
185
172.4
162.4
154.6
151.1
148.1
2500
413.7
398.5
340.4
308.4
287.3
270.7
257.6
251.9
246.9
Humidity Limits
0 to 100% RH.
Performance Specifications
Reference conditions
Range starting at zero, temperature 25
o
C (77
o
F), atmospheric pressure, power supply of 24 Vdc,
Silicone oil fill fluid, isolating diaphragms in 316L SS and digital trim equal to lower and upper range
values.
Accuracy
For ranges 2, 3, 4 and 5:
±0.075% of span (for span >= 0.1 URL)
±[0.0375 + 0.00375 URL/SPAN] % of span (for span < 0.1 URL)
For Level Transmitter:
± 0.08 % of span (for span
≥ 0.1 URL)
± [0.0504 + 0.0047 URL/span] % of span (for span < 0.1 URL)
For Insertion Transmitter:
±0.2% of span
Stability
±0.15% of URL for 5 years.
Temperature Effect
± [0.02 URL + 0.06% of span], per 20 ºC (68 ºF) for span >= 0.2 URL
± [0.023 URL+0.045% of span], per 20ºC (68 ºF) for span < 0.2 URL
For Level Transmitter:
6 mmH
2
O per 20
o
C for 4” and DN100
17 mmH
2
O per 20
o
C for 3” and DN80
Power Supply Effect
±0.005% of calibrated span per volt.
Mounting Position
Effect
Zero shift of up to 250 Pa (1 inH
2
O) which can be calibrated out. No span effect.
Electromagnetic
Interference Effect
Designed to comply with, Approved according to IEC61326-1:2006, IEC61326-2-3:2006, IEC61000-
6-4:2006, IEC61000-6-2:2005.
Physical Specifications
Electrical Connection
1/2 -14 NPT, PG 13.5, or M20 × 1.5. Other connections or request.
Process Connection
1/2 - 14 NPT - (Female or Male), G ½ A DIN 16288 Form B - Male or G ½ DIN 16288 Form
D - Male.
Содержание LD292
Страница 1: ......
Страница 2: ......
Страница 8: ...LD292 Operation and Maintenance Instruction Manual VIII...
Страница 11: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD292 Sanitary...
Страница 13: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD292 Level...
Страница 24: ...LD292 Operation and Maintenance Instruction Manual 2 4...
Страница 44: ...LD292 Operation and Maintenance Instruction Manual 3 20...
Страница 54: ...LD292 Operation and Maintenance Instruction Manual 4 10...
Страница 73: ...Appendix A A 7 CEPEL Centro de Pesquisa de Energia El trica...
Страница 74: ...LD292 Certifications Information A 8 FM Approvals...
Страница 76: ...LD292 Service Request Form B 2...