background image

EN

EN

5

6

Note: 

Open the rear cover of keypad will trigger tamper switch, please dismiss 

the alarm by following the disarm instruction on page 21-22.

2. When connected with electric door lock as an access control, 

keypad is suggested to use the specific power supply for access 

control.

To know connection steps, please refer to the instruction manual of 

electric door lock. The electric door lock and specific power supply 

for access control should be purchased respectively.

Connect Keypad to Control Panel

Make sure the control panel is in connecting state (please refer to 

the user manual of control panel), input user code or admin code 

on keypad, and then press any key of. 

[Arm] [Disarm] [Stay Mode]

The connection succeeds after one beep.
User can remotely control the panel via the keypad after connection.

Note: 

If the control panel beeps twice when connecting, it means the keypad 

has been already connected with the panel.

The default user code is 1234.

The default admin code is 123456.

Connect Keypad with RFID Tag

1. Input

 [admin code] 

+

 [#] 

to wake up keypad. 

Three beeps mean wrong input.
Wrong input for 6 times continuously, the keypad will be locked for 
20 seconds.

Содержание WK7000

Страница 1: ...RFID Tag to Keypad 6 Connect Electronic Door Lock 8 Installation 8 Settings 9 20 Enter Setup State 9 Exit Delay 10 Setting for SOS Key 11 Keyboard Tone 13 RFID Reader Setting 14 Direct Disarm by RFID...

Страница 2: ...ic door lock to work as an access control system for homes and offices When users are leaving house just close the door the electric lock will be locked automatically Before entering house just input...

Страница 3: ...face RFID reader Arm Disarm Stay mode SOS key RFID wake up key PR2600 LED indicator Positive and negative terminals for battery Battery compartment Tamper switch Wired cable interface RFID reader Arm...

Страница 4: ...ct Keypad to Control Panel Make sure the control panel is in connecting state please refer to the user manual of control panel input user code or admin code on keypad and then press any key of Arm Dis...

Страница 5: ...ad and then press down 9 for six seconds RFID tags are all cleared after one beep Connect Electric Door Lock To know connection steps please refer to the instruction manual of electric door lock Insta...

Страница 6: ...ou may trigger an alarm This setting does not apply to Stay Mode If the delay time of both control panel and keypad are set respectively the actual delay time is the total of both Exit Delay Enter set...

Страница 7: ...nds the setup is successful After setup you can press and hold the SOS key for 3 seconds the control panel will alarm immediately Input Code for SOS Enter setup state input 2 Verz gerungszeit 3 1 3 0...

Страница 8: ...LED indicator keeps on for 10 seconds the setup is successful Turn on Keyboard Tone Enter setup state input 4 1 When one beep is heard and the LED indicator keeps on for 10 seconds the setup is succes...

Страница 9: ...sh disarming without disturbing neighborhood Enter setup state input 5 2 When one beep is heard and the LED indicator keeps on for 10 seconds the setup is successful Note Default setting 1 turn on dis...

Страница 10: ...D indicator keeps on for 10 seconds the setup is successful Note Default setting 0 disable the function of direct disarm by RFID tag Change User Code Using user code can wake up keypad open electronic...

Страница 11: ...cessful Note Admin code is 6 digits default code is 123456 Reset After reset the user code admin code and other settings will restore to default except that the connected RFID tags can still disarm an...

Страница 12: ...an disarm alarm system by using keypad or by using RFID tags Using Keypad to Disarm Input user code or admin code and press Disarm key the LED indicator flashes once and the keypad beeps once and send...

Страница 13: ...ing code for SOS is set user just holds the SOS key for 3 seconds the LED indicator flashes once the keypad beeps once and the control panel alarms immediately If inputting code for SOS is set user ne...

Страница 14: ...works properly in case of emergency The keypad is neither waterproof nor moisture proof please install it in a shady cool and dry place The case of keypad is made of ABS Please keep it away from stro...

Страница 15: ...g the manual instruction Distance between keypad and control panel is too far Please move the keypad in a proper distance where control panel can receive the signal of keypad It s recommended to buy s...

Страница 16: ...xit switch Specifications Product Name Model No Power Supply Static Current Transmitting Current RFID Tags Supported Transmitting Distance Radio Frequency Housing Material Operating Condition Dimensio...

Отзывы: