6 Visual Inspection, Maintenance and Cleaning

Visual inspection

Check the inverter and cables for any visible signs of external damage. Contact your installer if you 
find any damage. Do not perform any repair work yourself.

Maintenance and cleaning

Ask your installer to check for correct inverter operation at regular intervals.
If the inverter is dirty and the visibility of the operating data and operating states of the inverter is only 
limited, clean the enclosure lid, the display and the LEDs with a damp cloth. Do not use any corrosive 
substances (e.g. solvents, abrasives) for cleaning.

Содержание SUNNY MINI CENTRAL 4600A

Страница 1: ...SMC46 60A BA BEN114230 TBEN SMC46 60A Version 3 0 EN PV inverter SUNNY MINI CENTRAL 4600A 5000A 6000A User Manual...

Страница 2: ......

Страница 3: ...Safety Instructions 8 2 3 Explanation of Symbols 9 2 3 1 Symbols on the Inverter 9 2 3 2 Symbols on the Type Label 10 3 Product Overview 11 4 Display 12 4 1 Operation 12 4 2 Display Messages during O...

Страница 4: ...Table of Contents SMA Solar Technology AG 4 SMC46 60A BA BEN114230 User Manual...

Страница 5: ...000A SMC 4600A 11 SMC 5000A 11 SMC 6000A 11 SMC 5000A IT SMC 6000A IT 1 2 Target group This manual is for the operator 1 3 Additional Information You will find additional information on the device spe...

Страница 6: ...ed will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation w...

Страница 7: ...nd cabling of protection class II Do not connect any energy sources other than PV modules to the Sunny Mini Central Do not use the Sunny Mini Central for purposes other than those described here Alter...

Страница 8: ...d only be carried out by a trained electrically skilled person Electrical installation Repair Modification CAUTION Risk of burns through contact with the enclosure during operation Only touch the encl...

Страница 9: ...ective Inform your installer An error has occurred Inform your installer immediately You can operate the display by tapping the enclosure lid Tapping once The background light switches on or the displ...

Страница 10: ...entation that accompanies the inverter The inverter must not be disposed of together with the household waste Further disposal information can be found in the enclosed installation manual CE mark The...

Страница 11: ...EN114230 11 3 Product Overview Position Designation A Display B Enclosure lid C LEDs Green LED Operation Red LED Ground fault or varistor defective Yellow LED Fault D Ventilation grid E Type label for...

Страница 12: ...ting one after the other and the configuration of the SMA Power Balancer 4 2 Display Messages during Operation After commissioning the inverter displays the device type the firmware version the config...

Страница 13: ...Status message MPP Current feed in power Voltage of the PV array After a further 5 seconds or after tapping the actual values of the reactive power Qac and of the displacement power factor cos PF are...

Страница 14: ...LED signals Status Description All LEDs are on The inverter is initializing All LEDs are off The DC input voltage at the inverter is too low for feed in All LEDs flashing The inverter is in the start...

Страница 15: ...id Operation interrupted Power limitation in the inverter Red LED on A ground fault has occurred or one of the thermally monitored varistors on the DC input side is defective Inform your installer Yel...

Страница 16: ...ct your installer if you find any damage Do not perform any repair work yourself Maintenance and cleaning Ask your installer to check for correct inverter operation at regular intervals If the inverte...

Страница 17: ...form your installer MPP The inverter is operating in MPP mode MPP is the standard display message when operating under normal radiation conditions MPP Peak The inverter is operating in MPP mode above...

Страница 18: ...of events that have occurred Fac Power frequency Error Identification of the actual disturbance error h On Total operating hours h total Total number of operating hours in feed in operation Iac Grid c...

Страница 19: ...of the MPP changes constantly depending on the level of radiation and cell temperature PV Abbreviation for photovoltaics SMA Power Balancer The SMA Power Balancer is a serial feature of the Sunny Min...

Страница 20: ...with the necessary assistance Inverter device type inverter serial number Type and number of connected PV modules Blink code or display message of the inverter Optional equipment e g communication pr...

Страница 21: ......

Страница 22: ......

Страница 23: ...product under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond sta...

Страница 24: ...USBMJB 1UZ UE XXX 4 VTUSBMJB DPN BV 4 FOFMVY 413 XXX 4 FOFMVY DPN 4 FJKJOH PNNFSDJBM P UE XXX 4 IJOB DPN 4 FDI 3FQVCMJD T S P XXX 4 FDI DPN 4 SBODF 4 4 XXX 4 SBODF DPN 4 FMMBT XXX 4 FMMBT DPN 4 C SJDB...

Отзывы: