Technical Information

Mechanical data

SMA Solar Technology AG

3/14

Sunny Central 400MV / 500MV / 630MV with medium-voltage switchgear

Sunny Central 400MV / 500MV / 630MV without medium-voltage switchgear

All figures in mm.

Sunny Central, DC cabinet

B

Sunny Central, inverter cabinet

C

Sunny Central, AC cabinet

D

Transformer

E

Medium-voltage switchgear

F

Station sub-distribution

G

COM-B, optional

All figures in mm.

Sunny Central, DC cabinet

B

Sunny Central, inverter cabinet

C

Sunny Central, AC cabinet

D

Transformer

E

Station sub-distribution

F

COM-B, optional

Содержание Sunny Central 1000MV

Страница 1: ...conditions that must be observed to ensure a smooth setup This document is valid for the following Sunny Central models Sunny Central 400MV Sunny Central 500MV Sunny Central 630MV Sunny Central 800MV...

Страница 2: ...thout medium voltage switchgear All figures in mm A COM B optional B Sunny Central DC cabinet C Sunny Central inverter cabinet D Sunny Central AC cabinet E Medium voltage switchgear F Transformer G St...

Страница 3: ...m voltage switchgear All figures in mm A Sunny Central DC cabinet B Sunny Central inverter cabinet C Sunny Central AC cabinet D Transformer E Medium voltage switchgear F Station sub distribution G COM...

Страница 4: ...ported by a semi trailer The semi trailer weighs 60 t with a length of 16 m a width of 3 m a height of 5 m and a ground clearance of 0 25 m At its final destination the surface must be dry solid and e...

Страница 5: ...rial dug out in such a way that the semi trailer and the crane are not hindered during transport The ground must have the following properties Approx 100 mm high Compression ratio 98 Soil pressure 150...

Страница 6: ...t Requirements SMA Solar Technology AG 6 14 The dimensions of the foundation can be found in the following graphic All figures in mm Sunny Central 800MV 1000MV 1250MV Sunny Central 400MV 500MV 630MV w...

Страница 7: ...Technical Information Transport Requirements SMA Solar Technology AG 7 14 Sunny Central 400MV 500MV 630MV without medium voltage switchgear...

Страница 8: ...l 800MV 1000MV 1250MV with medium voltage switchgear for ring switching A DC Input B Sunny Central C Transformer Dy11y11 D Medium voltage switchgear C C T E AC Output F External Grounding G Internal p...

Страница 9: ...V with medium voltage switchgear for cable switching A DC Input B Sunny Central C Transformer Dy11y11 D Medium voltage switchgear R T E AC Output F External Grounding G Internal power supply transform...

Страница 10: ...tral 800MV 1000MV 1250MV without medium voltage switchgear A DC Input B Sunny Central C MS Transformer Dy11y11 D AC Output E External Grounding F Internal power supply transformer optional G Station s...

Страница 11: ...V with medium voltage switchgear for ring switching A DC Input B Sunny Central C Transformer Dy11 D Medium voltage switchgear C C T E AC Output F External Grounding G Internal power supply transformer...

Страница 12: ...without medium voltage switchgear for cable switching A DC Input B Sunny Central C Transformer Dy11 D Medium voltage switchgear R T E AC Output F External Grounding G Internal power supply transforme...

Страница 13: ...DC Input B Sunny Central C Transformer Dy11 D AC Output E External Grounding F Internal power supply transformer optional G Station sub distribution H External power supply I Communication interface K...

Страница 14: ...ential equalization The AC connection is to be executed in compliance with the Installation Guide for the MV switchgear and or the transformer 4 Color All figures in mm RAL number Coloring Coloring us...