SMA Solar Technology AG
Electrical Connection
Installation Guide
SB16_21TL-IA-IEN112351
35
– Insert the DC connectors with sealing plugs into
the corresponding DC inputs on the inverter.
7. If an Electronic Solar Switch is installed, check it for
wear, as described in section 8.1 "Checking the
Electronic Solar Switch for Wear" (page 43), and
reattach it firmly.
☑ The PV array is now connected.
5.5 Communication
The inverter is equipped with a socket for communication interfaces in order to communicate with
special data logging devices (e.g., Sunny WebBox) or a PC with corresponding software (e.g., Sunny
Data Control or Sunny Explorer).
Refer to the communication interface manual for a detailed wiring diagram and a mounting
description.
NOTICE!
Manipulating the connector in the handle can damage the Electronic Solar
Switch.
The connector within the handle must remain movable in order to ensure proper contact.
Tightening the screw voids all warranty claims and creates a fire hazard.
• Do
not
tighten the connector screw in the Electronic Solar Switch handle.
NOTICE!
The Electronic Solar Switch can be damaged if it is attached incorrectly.
If it is not correctly attached, the Electronic Solar Switch can be damaged by high voltages.
• Plug the handle firmly onto the socket of the Electronic Solar Switch.
• Check that the handle is securely in place.