7 Commissioning
SMA Solar Technology AG
Operating manual
EDMM-10-BE-en-20
33
Procedure:
1. Activate the WLAN access point of the Data Manager. For this, tap on the enclosure lid twice.
☑ The COM LED is intermittently flashing orange and green for approx. 5 seconds. The
WLAN access point is then activated for approx. 30 minutes. Once this period has
expired, the WLAN access point is deactivated automatically.
2. Scan the QR code on the label included in delivery using your end device.
3. Confirm the connection to the WLAN access point of the Data Manager on your end device. It
may be necessary to deactivate the mobile data connection on your end device.
4. Open the web browser of your end device, enter the standard IP address 192.168.12.3 in
the address line of the web browser and press the enter key.
☑ The login page of the user interface opens.
7.2
Establishing a Connection via Ethernet in the local
network
Access addresses of the product
To connect a web browser to the product, the serial number of the product must be available.
The serial number is part of the access addresses of the product.
• Access address for Apple and Linux systems: SMA[serial number].local (e.g.
SMA0123456789.local)
• Access address for Windows and Android systems: https://SMA[serial number] (e.g.
https://SMA0123456789)
Requirements:
☐ The product must be connected to the local network via a network cable (e.g. via a router).
☐ The IPv4 protocol must be used.
☐ An end device (e.g. computer, tablet PC or smartphone) must be available.
☐ The end device must be in the same local network as the product.
☐ The respective latest version of one of the following web browsers must be installed: Chrome,
Edge, Firefox, Internet Explorer or Safari.
☐ JavaScript must be enabled in the web browser of the end device.
Procedure:
1. Open the web browser of your end device, enter the access address of the product in the
address line of the web browser and press the enter key.
2.
Web browser signals a security vulnerability
After the IP address has been entered, a message might appear indicating that the
connection to the user interface of the product is not secure. SMA Solar Technology AG
guarantees the security of the user interface.
• Continue loading the user interface.
☑ The login page of the user interface opens after a few seconds.