The suction line of your sprayer should contain a ‘siphon tube’ or intake tube which should be rotated so that it just touches the  

bottom of the tank surface. (see Detail Views). Reach in and rotate it, as needed, if not already in this position. 

 

A shut-off valve is threaded onto the pipe nipple at the intake location on the tank. It is at this location so you can shut off the flow  

of solution to access your system’s screen for cleaning. 

 

Checking/Cleaning the sprayer’s filter/screen: 

 

Start your pump and before it shuts off, reach down and shut the valve to the ‘Closed’ position (lever is perpendicular  

 

 

to the flow of fluid), then shut off your pump. 

 

Unscrew the knurled nut from the shut-off valve, leaving the valve connected to the tank. 

 

Swing (swivel) the intake assembly towards you. Look in the nut you JUST unscrewed. There is a screen/washer there. 

 

Remove the screen and clean as necessary. Replace when done and reassemble the entire assembly. 

 

Make sure the valve is turned to the ‘Open’ position before restarting your pump. 

‘Cut’ View of a ‘Typical’ Tank 

(looking inside) 

Intake/Siphon Tube/Screen Detail of a Typical L&G/ATV Sprayer (not including the ‘EC’Units) 

Cleaning the Check Valve

If you’re experiencing little to no pressure or the pump is not priming and you’ve checked your filter 

screen and it’s clean, and you’ve gone through the other trouble shooting tips, you may need to 

clean the check valve. 

 

Remove the head of the pump, which is held on by 7 screws. 

 

The first piece inside the head of the pump is called a check valve, it’s the part responsible for building up pressure 
and pumping water/solution through the lines.  

 

Clean the check valve under hot, soapy water (such as a good grade dish soap).  

 

Give it a very light scrubbing with something like an old toothbrush, something with soft bristles. 

 

Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble the pump. 

 

Most times this will restore most, if not all of the prime of a pump. 

If you’re still having issues with pressure after this step, it would be recommended to replace this part. 

Checking the Pressure Switch

If your motor is not running and you’ve checked the following: for loose wiring connections, fuse, the switch on 

the lead wire was “ON” and made sure you were connected to a fully charged battery and everything is fine, but 

the motor won’t run, then it’s time to check to see if the pressure switch is bad. 

 

Remove the cover off the 1” square box (pressure switch) on the head of the pump, the cover is held on by 
one phillips-head screw. This will expose the two red wires. 

 

With the pump connected to a good 12 volt power source and everything on. 

 

Slip the two red wires off the terminals and touch them together.  

 

If the motor runs, it means the pressure switch is bad and needs to be replaced.  

If it still doesn’t run, try bypassing the switch in the lead wire or using another lead wire. Even if a tester shows 

power to the pressure switch, it still could be the switch in the wire that is causing the problem. If still not  

responsive, use a voltmeter or electrical tester to make sure you are getting power to the head of the pump, as 

it could possibly be something in one of the wires or even the lead wire assembly may need to be replaced. 

 

Warning:

 It is NOT recommended to run the pump this way, as the pump will continue to run and 

not shut off.  

 

This could result in blown hoses when all discharges are closed. 

Also, this could result in premature failure of the pump completely. 

Содержание 5301790

Страница 1: ...ORTANT REMINDER This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the Detail A OWNER S MANUAL General Information Thank you for purchasing this product The purpose of this manual is to assist you in operating and maintaining your lawn garden ATV sprayer Retain a copy of your receipt for your unit as it w...

Страница 2: ...rayer s carton 800 ATV25DXBL 5301790 Contents of Parts Bag 5278137 Contents of Bracket Kit 5278138 Wet Boom Sub Assembly 5275712 Tank Plumbing Pre Assembly Owner s Manual End Nozzle 5275122 Pkg of 2 5275713 Lid w Lanyard 5058188 ...

Страница 3: ... cam handles which extend beyond the back of the tank are facing you and just hanging over the edge of the table or flat surface you are assembling this on Secure the boom mounting brackets 5038873 to the tank mounting brackets with Cam handles as shown in Detail A You can position them as needed within the slot on the bracket Just be sure that the surfaces of both brackets are even with each othe...

Страница 4: ...ition Note The check valve diaphragm can fall out during transport if the knob is not turned to the ON or OFF position Step 4 1 Start by sliding Item 4 3 2 onto the boom tube Item 1 as shown leaving about 1 2 to 3 4 between the end of the boom tube and Item 2 Make sure the Long portion of Item 3 is facing the nozzle end 2 Slide the complete end nozzle assembly onto the stainless steel boom tube wi...

Страница 5: ...ge Hand tighten securely DO NOT OVER TIGHTEN Detail B Screw the lid onto the tank Place the end of the lanyard through the tab in the tank This is so the lid can hang off the tank when filling rinsing the tank out Detail C Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hole in the clip and bri...

Страница 6: ...Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that is pre set at the factory to shut the pump off when all discharges are closed The pump will turn back on when one of the following actions occurs Handgun lever is squeezed to spray the handgun Boom valve is opened to broadcast spray with the boom By...

Страница 7: ...nto the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system including the bypass Make sure to operate the boom and handgun until you see pink fluid spraying from the nozzles Leave any remaining antifreeze in the tank Before your next usage rinse the antifreeze from the sprayer with clean water It is nearly impossible to drain all of the water f...

Страница 8: ...r defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge...

Страница 9: ... valve under hot soapy water such as a good grade dish soap Give it a very light scrubbing with something like an old toothbrush something with soft bristles Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step...

Страница 10: ...Page 10 Exploded View Parts List 800 ATV25DXBL 5301790 Intake Detail Manifold Detail ...

Страница 11: ...Page 11 Boomless Wet Boom Assembly Exploded View Parts List 5275260 Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122 ...

Страница 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: