background image

5. Reconnect wires.

Connect the Themo thermostat according to the 

connection diagram.

TipIf you are replacing an existing thermostatuse the

stickers as a guide when inserting the wires into the

Themo terminal blocks.

The wires from the wall should plug easily into the  terminal 

blocks. Use a screwdriver to tighten the terminal screws. 

Fasten the thermostat firmly to a flush mounted wall box or 

an exterior wall box by driving the screws through the holes 

in each side of the thermostat. 

14

Note: The screen of the heat-

ing cable must be connected 

to the earth conductor of the 

power supply cable using a 

separate connector (capped 

with wire nuts).

Содержание themo

Страница 1: ...themo INSTALLATION AND OPERATION MANUAL ...

Страница 2: ...Table of contents 4 5 6 7 8 17 18 19 20 1 Technical Specifications 2 Safety Instructions 3 Mounting Instructions 4 Configuring 5 Warranty 6 Disposal Instructions 2 ...

Страница 3: ...es including all amendments and with national legislation implementing these directives Low Voltage Directive 2014 35 EC EMC Directive 2014 35 EC The following harmonized standards were applied EMC EN 55024 2011 EMC EN 55022 2011 Safety IEC 60950 1 Said object complies with Directive 2011 65 EC RoHS 2 Restriction of Hazardous Substances in Electrical and Electronic Equipment ...

Страница 4: ...25 C NTC 12 kOhm at 25 C NTC 15 kOhm at 25 C NTC 22 kOhm at 25 C NTC 33 kOhm at 25 C NTC 47 kOhm at 25 Cable specification max 1x4 mm 2 4 Temperature range Offline manual mode 13 41 C Online automatic mode 5 45 C Dimensions W70 x L70 x H48 mm Weight 120 g Terminal block screw tightening torque 0 5Nm Radio IEEE802 11 b g n 2 4GHZ 2 5GHZ Buttons 1x Capacitive Touch Material ABS PC ...

Страница 5: ...1 Protection class Class II OPERATING RESTRICTIONS Altitude 2000m above sea level Ambient Temperature 0 40 C Level of pollution 2 Humidity Max 85 relative humidity STORAGE CONDITIONS Ambient Temperature 10 C to 50 C Rel Humidity 5 to 85 non condensing ...

Страница 6: ... floor or similar material always use a floor sensor and never set the floor temperature to more than 35 C Please note the following The installation of the thermostat must be carried out by an authorized and qualified installer according to local regulations The thermostat must be connected to a power supply via all pole disconnection switch Always connect the thermostat to continuous power suppl...

Страница 7: ...and excessive heat Children should be supervised to ensure that they do not play with the thermostat Cleaning and user maintenance should not be made by children without supervision NB THEMO requires working Wi Fi in order to perform full functionality 7 ...

Страница 8: ...unting Instructions 1 Switch off power Switch off power to your heating equipment at your circuit breaker box Verify that your existing thermostat should not be able to display any indication of operation 8 ...

Страница 9: ... t have an existing thermostat skip to step 3 Remove the cover of your old thermostat to reveal the wiring Most covers snap off easily but some may be attached by screws Screws are most commonly hidden behind the adjustment button 9 ...

Страница 10: ...__________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ Use the stickers provided in this guide to label the wires for connection to Themo thermostat If your old thermostat has more than one wire coming out from each connector or you need ad...

Страница 11: ...11 ...

Страница 12: ...all using a screwdriver Pull the thermostat wires out as far as possible Note Do not disconnect any capped wires which connect the screen of the heating cable and the earth conductor of the power supply cable The exposed part of the wire should be trimmed between 1 cm and 1 5 cm Ensure the exposed wire is straight 12 ...

Страница 13: ...13 Q Q LO D N LO D L I I ...

Страница 14: ...wires from the wall should plug easily into the terminal blocks Use a screwdriver to tighten the terminal screws Fasten the thermostat firmly to a flush mounted wall box or an exterior wall box by driving the screws through the holes in each side of the thermostat 14 Note The screen of the heat ing cable must be connected to the earth conductor of the power supply cable using a separate connector ...

Страница 15: ...15 Carefully fit the thermostat to the in wall socket and tighten the screws ...

Страница 16: ... assembling the front panel to the base Push the front panel in place When connecting the front panel to the base make sure that the female header will not bend the connectors Press carefully until the front panel is fixed against the frame 16 ...

Страница 17: ...17 7 Switch on power Switch on the power to your heating equipment at your circuit breaker box Watch Themo come alive ...

Страница 18: ...18 4 Configuring Download Themo mobile app to create a free account and follow the step by step instructions on screen to set up your device app themo io setup Or go to webpage ...

Страница 19: ...pective reseller will have 2 year limited warranty When using or installing the product it is required to follow instructions in this guide Only manufacturing defects which can be traced back to the manufacturer will be under warranty Warranty is void when the product has been damaged or used incorrectly ...

Страница 20: ...20 6 Disposal Instructions Please consider the environment and recycle your old thermostat ...