60W2 12 VDC Power Supply
Installation Guide for PN 701507-60W2 – NEC Class 2 Output
PAGE 2 OF 2
Customer service and technical support
888.747.4LED (888.747.4533)
SloanLED.com • [email protected]
Europe: Customer service and technical support
+31 88 12 44 900
SloanLED.com • [email protected]
P/N
401984 Rev
A 2016-10-12
Some or all of the products shown are covered by U.S. and foreign patents pending and covered by one of more of the following U.S. patents issued: 6776504, 6969179, 7192157, 6932495, 7241031
SloanLED products carry a limited warranty.
For complete details refer to the warranty policy found at SloanLED.com
6.
Connect Primary:
CAUTION:
Have a licensed
electrician connect primary.
7.
Make secondary connections:
Secondary
class 2 cables do not require conduit per
NEC 2008 Articles 725.121 through 725.130.
Seal all wall penetrations with silicone to
avoid water damage.
TROUBLESHOOTING
If sign is not functioning properly, check the following:
• Primary voltage is between 100-277 VAC
• Secondary voltage is 12 VDC
• Output current is 5 Amps or less
• Power supply is not overloaded (see power supply capacity chart
in product installation guide or SloanLED.com)
• There are no shorts in secondary wiring
• All secondary connections are RED-TO-RED and BLACK-TO-BLACK
UL File number: E336107 UL8750
E215393 UL879
Power supply
Primary
power
UL listed
junction box
Wall penetration
(seal with silicone)
Sign or
channel letter
Connect secondary
output. Ensure all
secondary connections
are RED-TO-RED (+)
and BLACK-TO-
BLACK (-)
All manuals and user guides at all-guides.com