5
Install Flush Connection (Figure 1)
A 1 1/2” pipe connection (NOT supplied by Sloan) must be used to connect the
fixture inlet from the wall to the flush connection.
Secure flanged end of the F-100/F-102 Flush Connection to the 1 1/2” pipe using
a 1 1/2” F-2-A Coupling with S-21 Gasket and Coupling nut. Tighten securely.
DUE TO THE HIGH BACK PRESSURES THAT CAN BE CREATED
BY STAINLESS WATER CLOSETS AND COMBINATION FIXTURES,
THE FOLLOWING PROCEDURES MUST BE FOLLOWED WHEN
INSTALLING THE FLUSH CONNECTION. FAILURE TO FOLLOW
THESE PROCEDURES CAN RESULT IN SEPARATIONS. FOR
SECURE CONNECTIONS IN HIGHER PRESSURE AND OTHER
SEVERE CONDITION APPLICATIONS, THE FLUSH CONNECTIONS
CAN BE SWEAT SOLDERED. REMOVE ALL PLASTIC AND
RUBBER GASKETS BEFORE BEGINNING SOLDERING PROCESS.
!!! IMPORTANT !!!
IMPORTANT: BEFORE INSERTING THE SCORED ENDS
INTO THE ELBOW, APPLY SEVERAL DROPS OF LOCTITE
(SUPPLIED BY SLOAN) TO THE SCORED ENDS OF THE
TUBES (FIGURE 3). THIS SEALANT HELPS PREVENT
SEPARATION UNDER HIGH-PRESSURE CONDITIONS. DO
NOT USE ANY OTHER PIPE SEALANT OR LUBRICANT ON
THIS CONNECTION.
!!! IMPORTANT !!!
Items shown by dashed lines are not supplied by Sloan
FIXTURE SIDE
OF WALL
1-1/2”OR 3/4”
I.P.S. PIPE
CONNECTION
(NOT SUPPLIED
BY SLOAN)
S-21 GASKET
F-2-A
COUPLING NUT
F-100 FLUSH CONNECTION*
(SUPPLIED 3-1/4” LONG)
B
Apply Loctite to
scored ends of
tubes
1-1/2” OR
3/4” I.P.S. PIPE
CONNECTION
(NOT SUPPLIED
BY SLOAN)
ELBOW
F-100 FLUSH CONNECTION
VACUUM
BREAKER
F-2-A
COUPLING NUT
F-100 FLUSH
CONNECTION
SLIP JOINT
COUPLING
VACUUM
BREAKER
ELBOW
RUBBER
GASKET
RUBBER
GASKET
NYLON
SLIP
GASKET
COUPLING
NUT
NYLON
SLIP
GASKET
COUPLING
NUT
IMPORTANT: WHEN CUTTING SCORED
TUBES TO FIT, ALWAYS KEEP AT
LEAST 1-1/4” (32 mm) OF SCORING TO
ASSURE PROPER ENGAGEMENT WITH
COMPRESSION COUPLING.
Install Slip Elbow (Figure 2)
Connect scored ends of vacuum breaker tube and F-100/F-102 flush
connection to the elbow using coupling, slip gasket and rubber compression
gasket. After applying Loctite® to scored ends, tighten securely.
Figure 2
Loctite can also be used to secure Push Button Flange. See
Sealant package for details.
Figure 3
RUBBER
GASKET
NYLON
SLIP
GASKET
COUPLING
NUT
When cutting Vacuum breaker and F-100/F-102 Flush Connection
tubes to fit, always keep at least 1 1/4” (32 mm) of scoring to assure
proper engagement with compression coupling (see Figure 2).
A
Figure 1
5
Install Vacuum Breaker & Flush
Connection