3
1
Install Optional Sweat Solder
Adapter (only if your supply pipe
does not have a male thread)
2
Install Cover Tube and Wall
Flange to supply pipe
With the exception of Control Stop Inlet, DO NOT use pipe sealant or
plumbing grease on any valve component or coupling!
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers — DO NOT
USE toothed tools to install or service these valves. Use a Sloan A-50
Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud
wrench to secure all couplings. Also see “Care and Cleaning” section
of this manual.
!!! IMPORTANT !!!
This product contains mechanical and/or electrical components that
are subject to normal wear. These components should be checked
on a regular basis and replaced as needed to maintain the valve’s
performance.
!!! IMPORTANT !!!
If you have questions about how to install your Sloan Flushometer,
consult your local Sloan Representative or call Sloan Installation
Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614) OR 1-847-233-2016
A
Measure from finished
wall to C/L of Fixture
Spud. Cut pipe 1¼”
(32 mm) shorter than
this measurement.
Chamfer O.D. and I.D.
of water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter
fully onto pipe.
C
Sweat solder the
Adapter to pipe.
WATER
SUPPLY PIPE
SWEAT
SOLDER ADAPTER
COVER TUBE
WALL
FLANGE
SET SCREW
A
Measure from finished wall to first thread of Adapter or
threaded supply pipe (dimension “X”). Cut Cover Tube to
this length.
B
Slide Cover Tube over pipe. Slide Wall Flange over Cover
Tube until against wall.
Thread Control Stop onto supply pipe. Tighten with a wrench
until outlet is positioned as required.
A
3
Install Control Stop
CONCEALED
EXPOSED
SET
SCREW
SUPPLY
FLANGE
IRON PIPE NIPPLE OR COPPER PIPE
WITH SWEAT SOLDER ADAPTER
COVERING
TUBE
BAK-CHEK
®
CONTROL
STOP
BAK-CHEK
®
CONTROL STOP
IRON PIPE NIPPLE
OR COPPER PIPE
WITH SWEAT SOLDER
ADAPTER
Never open Control Stop to where the flow from the valve
exceeds the flow capability of the fixture. In the event of a
valve failure, the fixture must be able to accommodate a continuous
flow from the valve.
!!! IMPORTANT !!!
Tighten Set Screw with a 1/16” hex wrench. For Exposed
Flushometers — DO NOT install Vandal Resistant Stop Cap
at this time.
B