background image

Code No. 0816302

Rev. 3b (11/08)

INSTALLATION INSTRUCTIONS FOR 

SENSOR ACTIVATED LAVATORY FAUCETS

LIMITED WARRANTY

Sloan Valve Company warrants its EBF-85 and EBF-187 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the
service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of
purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer's
cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or
organizations who purchase Sloan Valve Company's products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries (battery operated
models).

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES
OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLATION

Prior to installing the Sloan EBF-85 or EBF-187 Faucet, install the items
listed below. Also, refer to the Rough-In illustrations on Page 2.
• Lavatory/sink
• Drain line
• Hot and cold water supply lines or tempered water supply line

Mixing Valve

When installing the faucet with a Sloan mixing valve, these Installation
Instructions AND the Installation Instructions packaged with the mixing
valve MUST be followed.

Important:

• INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES

AND REGULATIONS.

• KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT

COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON
COMPRESSION FITTINGS. FOR THREADED PIPE FITTINGS, DO NOT
APPLY SEALANT TO THE FIRST TWO “STARTER” THREADS.

• FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING

SOLENOID TO SUPPLY STOPS.

DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETELY
INSTALLED.

If the batteries are installed before the fiber optic cable has

been connected to the valve module, the faucet will not properly set the
sensing range for the sink on which it is installed.

DO NOT INSTALL THE SPRAY HEAD UNTIL AFTER THE SUPPLY LINES
HAVE BEEN FLUSHED.

BAK-CHEK

®

TEE USAGE

When connecting the Sloan EBF-85 or EBF-187 Faucet to both hot and cold
water supplies, a Bak-Chek

®

Tee is provided and required as illustrated in

the Rough-in illustrations on Page 2. Water temperature can be controlled
by adjusting the supply stops.
When connecting the faucet to a single line water supply or a pre-tempered
water supply, a Bak-Chek

®

Tee is not required.

A Bak-Chek

®

Tee is not required or provided when a Temperature Mixing

Valve is included with the faucet.

TOOLS REQUIRED FOR INSTALLATION

• Open end wrenches for hex sizes: 1/2”, 9/16”, 5/8”, 15/16”
• Basin wrench
• Phillips head screwdriver, #2
• Hammer (if installing plastic or hollow wall anchors to mount valve

module)

• 0.05” hex wrench (supplied)
• Spray head key (supplied)
• 1/4” drill bit (if plastic wall anchors are used to mount valve module)
• 5/16” drill bit (if hollow wall anchors are used to mount valve module)
• 3/8” drill bit (if toggle nut anchors are used to mount valve module)

Model EBF-85

Battery Powered, Sensor Activated Lavatory Faucet

Furnished with a Black Plastic Throat Plate

Model EBF-187

Battery Powered, Sensor Activated Lavatory Faucet

Furnished with a Chrome Plated Metal Throat Plate

Compliant to: ASME A112.18.1
and CSA B125.1

Содержание OPTIMA plus Series

Страница 1: ...G IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS FOR THREADED PIPE FITTINGS DO NOT APPLY SEALANT TO THE FIRST TWO STARTER THREADS FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING SOLENOID TO SUPPLY STOPS DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETEL...

Страница 2: ...nderside of Trim Plate to prevent Faucet from rotating C Insert Trim Plate Bolts through the 4 inch 102 mm spread deck holes and Faucet Shank through the 1 inch 25 mm minimum diameter deck hole Secure Trim Plate to Deck using the large Plate Washers and Hex Nuts supplied Secure Faucet from below Deck using the Flange Nut supplied ROLL PIN RUBBER FAUCET GASKET COVER PLATE BLACK PLASTIC BASE PLATE D...

Страница 3: ...all Bracket in an appropriate location as shown in the Rough In illustrations on Page 2 WALL BRACKET BASE WALL BRACKET SELF TAPPING SCREW PLASTIC ANCHOR WITH SCREW AND WASHER SHOWN B Position Wall Bracket within 20 inches 508 mm from Faucet When installed the Fiber Optic Cable from the Faucet Spout to the Valve Module should have some slack C Use Wall Bracket Base as a template to mark off holes o...

Страница 4: ... water line connections VALVE MODULE WALL BRACKET BASE WALL BRACKET SELF TAPPING SCREW 6 Connect Supply Line s from Supply Stop to Solenoid Valve Inlet C Reattach the Battery Compartment to the Valve Module by aligning the arrow on the Battery Compartment with the arrow on the solid tab of the Valve Module D Secure by tightening Battery Compartment Coupling Ring To deter unauthorized removal of ba...

Страница 5: ...ration procedure should start automatically after proper electrical connections are made Start Up 8 A Remove Spray Head B Open supply stop s then activate Faucet for 30 seconds by placing hands in front of sensor The Solenoid Valve should click the Valve Module should beep and water should flow from the Spout If this does not occur refer to the Troubleshooting section of this instruction instructi...

Страница 6: ... deter unauthorized removal of batteries use a 0 05 hex wrench to tighten the security set screw on the Coupling Ring Upon installation of the batteries the EBF 85 and EBF 187 faucet will begin a new self calibration procedure see START UP MODE SOLENOID SCREEN FILTER CLEANING PROCEDURE A Unscrew the Filter Cap and remove it from the Solenoid Valve Housing and carefully pull the Screen Filter with ...

Страница 7: ...ive SOLUTION Replace Solenoid Valve Module Replace EBF 11 A Solenoid Valve Module INDICATOR Module produces audible BEEPs when a target is placed in the detection zone of the Sensor and Solenoid Valve produces an audible CLICK but NO water flows CAUSE Water supply to faucet is not open SOLUTION Open supply stop s completely CAUSE Bak Chek is installed backward SOLUTION Reinstall Bak Chek properly ...

Страница 8: ...and Sensor Assembly EBF 187 with CP Metal Throat Plate EBF 1009 A Fiber Optic Sensor Cable Assembly Only replaces EBF 12 A includes lens holder 2 ETF 1021 A 0 5 gpm 1 9 Lpm Spray Head with Key female thread ETF 1022 A 2 2 gpm 8 3 Lpm Aerator Spray Head with Key female thread ETF 1027 A 2 2 gpm 8 3 Lpm Laminar Flow Spray Head female thread ETF 435 Replacement Key ONLY for ETF 1021 A and ETF 1022 A ...

Отзывы: