background image

6

1

1.. P

PR

RO

OB

BLLEEM

M::

C

Coonnttrrooll  M

Moodduullee  ttrroouubblleesshhoooottiinngg  bbeeeeppeerr  ddooeess  nnoott  ffuunnccttiioonn  ((nnoo  aauuddiioo

““bbeeeeppss””  ssoouunndd  dduurriinngg  ffaauucceett  iinniittiiaalliizzaattiioonn,,  bbaatttteerryy  iinnssttaallll  oorr  aafftteerr  rreesseett
bbuuttttoonn  iiss  pprreesssseedd))..

CAUSE:

No battery power is being supplied to Control Module.

SOLUTION:

Ensure that the batteries are installed properly into the Control Module.
Check that the orientation of each battery matches the positive (+) and
negative (-) symbols shown on the bottom of the Battery Compartment.
Reinsert the Battery Compartment into the Control Module. Make sure the
Battery Connector is securely attached to the Battery Compartment. An
audio “beep” should sound 6 times.

CAUSE:

Insufficient battery power is being supplied to Control Module.

SOLUTION:

One (or more) of the batteries is “dead.” To ensure proper operation,
insert four (4) new C-size Alkaline batteries. Check that the orientation of
each battery matches the positive (+) and negative (-) symbols shown
on the bottom of the Battery Compartment. Reinsert the Battery
Compartment into the Control Module. Make sure the Battery Connector
is securely attached to the Battery Compartment. An audio “beep” should
sound 6 times.

2

2.. P

PR

RO

OB

BLLEEM

M::

FFaauucceett  ddooeess  nnoott  ddeelliivveerr  aannyy  w

waatteerr  w

whheenn  S

Seennssoorr  iiss  aaccttiivvaatteedd..

IIN

ND

DIIC

CAATTO

OR

R::

S

Soolleennooiidd  vvaallvvee  pprroodduucceess  aauuddiibbllee  ““C

CLLIIC

CKK..””

CAUSE:

Water supply valve is closed.

SOLUTION:

Open supply stop(s) completely.

IIN

ND

DIIC

CAATTO

OR

R::

S

Soolleennooiidd  vvaallvvee  D

DO

OEES

S  N

NO

OTT  pprroodduuccee  aann  aauuddiibbllee  ““C

CLLIIC

CKK..””

CAUSE:

Solenoid lead is not properly connected to the Control Module.

SOLUTION:

Disconnect and reconnect Solenoid lead to the Control Module.

CAUSE:

Batteries are not installed properly.

SOLUTION:

Check that the orientation of each battery matches the positive (+) and
negative (-) symbols shown on the bottom of the Battery Compartment.
Reinsert the Battery Compartment into the Control Module. Make sure the
Battery Connector is securely attached to the Battery Compartment. An
audio “beep” should sound 6 times.

3

3.. P

PR

RO

OB

BLLEEM

M::

FFaauucceett  ddeelliivveerrss  oonnllyy  aa  sslloow

w  fflloow

w  oorr  ddrriibbbbllee  w

whheenn  S

Seennssoorr  iiss  aaccttiivvaatteedd..

CAUSE:

Water supply valve is partially closed.

SOLUTION:

Open supply stop(s) completely.

CAUSE:

Solenoid Filter is clogged.

SOLUTION:

Remove, clean, and reinsert. Replace EBF-1004-A Solenoid Filter Kit if
necessary.

CAUSE:

Aerator or Spray Head is clogged.

SOLUTION:

Remove, clean, and reinsert.

4

4.. P

PR

RO

OB

BLLEEM

M::

FFaauucceett  ddooeess  nnoott  ssttoopp  ddeelliivveerriinngg  w

waatteerr  oorr  ccoonnttiinnuueess  ttoo  ddrriipp  aafftteerr  uusseerr  iiss

nnoo  lloonnggeerr  ddeetteecctteedd  ((aauuttoom

maattiicc  sshhuutt--ooffff  ffaaiillss  eevveenn  w

whheenn  bbaatttteerriieess  aarree

rreem

moovveedd))..

CAUSE:

Solenoid Valve has been connected backwards.

SOLUTION:

Disassemble Solenoid Valve compression fittings at both the inlet and
outlet positions. The water should flow from inlet through the Solenoid
Valve to the outlet according to the direction of the arrow shown on the
side of the Solenoid Valve. Reconnect the compression fittings in the
correct orientation.

CAUSE:

Solenoid Valve is dirty.

SOLUTION:

Backflush by reversing water flow (opposite to the direction shown by the
arrow on the side of the Solenoid Valve) through the Solenoid Valve.
Reconnect the compression fittings in the correct orientation. Activate
faucet.

CAUSE:

Solenoid Valve Module is defective.

SOLUTION:

Replace Solenoid Valve Module.

5

5.. P

PR

RO

OB

BLLEEM

M::

TThhee  w

waatteerr  tteem

mppeerraattuurree  iiss  ttoooo  hhoott  oorr  ttoooo  ccoolldd  oonn  aa  ffaauucceett  ccoonnnneecctteedd  ttoo

hhoott  aanndd  ccoolldd  ssuuppppllyy  lliinneess  w

wiitthh  B

Baakk--C

Chheekk

®

®

TTeeee..

CAUSE:

Supply stops are not adjusted properly.

SOLUTION:

Adjust supply stops.

N

NO

OTTEE::

FFoorr  ssoom

mee  ssyysstteem

mss,,  aa  tthheerrm

moossttaattiicc  m

miixxiinngg  vvaallvvee  m

maayy  bbee  rreeqquuiirreedd..

For additional information about Sloan Mixing Valves or Trim Plates, consult our
Installation Instructions or Maintenance Guides.

If further assistance is required, please contact the Sloan Valve Company
Installation Engineering Department at:

1-888-SLOAN-14 (1-888-756-2614)

The ERF-885 faucet is factory set so there should be no need for adjustments;
however, if an adjustment is required, refer to the following instructions.

Reset Button and Time-out Setting Switch 

(Figure 13)

R

REES

SEETT  B

BU

UTTTTO

ON

N  —

— The Reset Button is used whenever it is necessary to rematch

the Control Module’s RF ID to the Spout’s RF ID. When the Reset Button is
pressed, an audio “beep” will sound. Pass hand under Spout to initialize the
Faucet. Two audio “beeps” will sound to acknowledge that the Control Module
has recognized the Spout. For the first ten minutes, the unit will “beep” when a
valid target is detected.
TTIIM

MEE--O

OU

UTT   S

SEETTTTIIN

NG

G   S

SW

WIITTC

CH

H   —

— The Faucet Time out Setting determines the

maximum time faucet will run upon continuous detection. Faucet is factory set
at the 30 second time out. Position switch to the right for a 20 minute time out.

Range Adjustment 

(Figures 14 and 15)

The OPTIMA 

Plus

®

ERF-885 Faucet is factory set to operate when hands are

placed 6-1/2 to 7 inches (165 to 178 mm) from Sensor. This range should be
satisfactory for most installations. If range adjustment is required, refer to the
following procedure.

The Range Potentiometer is located in the Throat Plate (Figure 14).

Turn off water supply. Remove Throat Plate as follows and as illustrated in Figure
14. Remove the Spray Head using the Key provided. Remove the hex screw
located in the Spray Head opening of the Throat Plate. Remove the Throat Plate
from the Faucet Housing.

IIm

mppoorrttaanntt:: Range Potentiometer adjustment screw rotates only 3/4 of a turn; DO

NOT over-rotate.

Turn Range Potentiometer counterclockwise to decrease range or clockwise to
increase range.
Place Throat Plate next to the Faucet Housing and cycle Faucet several times to
assure that the Sensor range does not inadvertently pick up reflection off the
edge of the sink. If reflection occurs, slightly adjust Range Potentiometer
counterclockwise and again cycle Faucet.
Repeat adjustment procedure until desired range is achieved.
Reinstall the Throat Plate and secure using the hex screw. Install the Spray Head
using the Key provided.

R

RA

AN

NG

GEE  P

PO

OTTEEN

NTTIIO

OM

MEETTEER

R

• TURN CLOCKWISE TO

INCREASE RANGE

• TURN COUNTERCLOCKWISE

TO DECREASE RANGE

Figure 15

M

MO

OD

DEE  P

PO

OTTEEN

NTTIIO

OM

MEETTEER

R  ((2

2  P

PO

OS

SIITTIIO

ON

N))

• ON DEMAND

(TURN TO LEFT POSITION)

• METERED

(TURN TO RIGHT POSITION)

R

REES

SEETT  B

BU

UTTTTO

ON

N —

RESETS THE CONTROL
MODULE’S RF ID TO MATCH
THE SPOUT’S RF ID

TTIIM

MEE--O

OU

UTT  S

SEETTTTIIN

NG

G  S

SW

WIITTC

CH

H —

30 SECONDS OR 20 MINUTES
(DETERMINES MAXIMUM TIME
FAUCET WILL RUN UPON
CONTINUOUS ACTIVATION)

Figure 13

Figure 14

SPRAY HEAD

HEX SCREW

THROAT

PLATE

IIM

MP

PO

OR

RTTA

AN

NTT:: RANGE

POTENTIOMETER
ADJUSTMENT SCREW
ROTATES ONLY 3/4 OF
A TURN; DO NOT OVER-
ROTATE.

TROUBLESHOOTING GUIDE

ADJUSTMENT PROCEDURES

Содержание OPTIMA plus ERF-885

Страница 1: ...Activated Wireless Lavatory Faucet makes wash up totally hands free providing the ultimate in sanitary protection and automatic operation The OPTIMA Plus Faucet uses Active and Passive Infrared sensi...

Страница 2: ...ordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does...

Страница 3: ...DES AND REGULATIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS Tools Req...

Страница 4: ...Nuts supplied Secure Faucet from below Deck using the Flange Nut supplied Remove the Control Module Cover from the Control Module Base Remove the Battery Connector from the Battery Compartment Remove...

Страница 5: ...pply tubes and supply stops furnished by installer Tighten Compression Fittings securely Install a 3 8 inch 10 mm copper supply tube between the Bak Chek Compression Tee and the inlet side of the Sole...

Страница 6: ...5 Figure 12 CONTROL MODULE I IM MP PO OR RT TA AN NT T ALL FOUR 4 COVER SCREWS MUST BE INSTALLED INSTALL COVER AND SECURE WITH THE FOUR 4 COVER SCREWS Figure 9 GENTLY SLIDE THE BATTERY COMPARTMENT INT...

Страница 7: ...posite to the direction shown by the arrow on the side of the Solenoid Valve through the Solenoid Valve Reconnect the compression fittings in the correct orientation Activate faucet CAUSE Solenoid Val...

Страница 8: ...urn off water supply Remove Throat Plate as follows and as illustrated in Figure 14 Remove the Spray Head using the Key provided Remove the hex screw located in the Spray Head opening of the Throat Pl...

Страница 9: ...lacement Kit EBF 1011 A Solenoid Replacement Kit includes Solenoid Body Solenoid Enclosure and Solenoid Filter Plug EBF 1004 A Solenoid Filter Replacement Kit includes Filter Screen Assembly and O rin...

Отзывы: