4
With Control Module Cover removed, use the Control Module Base as a template
to mark locations on wall for Mounting Fasteners. Determine the appropriate
Mounting Fastener for the particular wall type (three different fastener types are
included; see parts list). Drill four (4) appropriately sized holes.
For Plastic Wall Anchor — 1/4" (6 mm) holes
For Hollow Wall Anchor — 5/16" (8 mm) holes
For Toggle Nut Anchor — 3/8" (10 mm) holes
Attach Control Module Base to wall using the appropriate fastener.
IIM
MP
PO
OR
RTTAAN
NTT:: KKeeeepp tthhrreeaadd sseeaallaanntt oouutt ooff yyoouurr w
waatteerrw
waayy ttoo pprreevveenntt ccoom
mppoonneenntt
ppaarrtt ddaam
maaggee!! D
DO
O N
NO
OTT uussee aannyy sseeaallaanntt oonn ccoom
mpprreessssiioonn ffiittttiinnggss..
N
Noottee:: Flow direction of Solenoid Valve is indicated by an arrow on Valve Body.
N
Noottee:: If installation includes a Sloan mixing valve, refer to the Installation
Instructions supplied with the Sloan mixing valve.
CONNECT WATER SUPPLY LINE FROM SPOUT TO SOLENOID VALVE
Install the 1/4 inch end of the 1/4 to 3/8 inch Compression Fitting onto the
Spout’s copper supply tube. (Refer to Figures 1A and 6.)
Connect 3/8 inch O.D. supply tube between Compression Connection on
Solenoid Valve and Compression Fitting on the Spout’s copper supply tube.
(Supply tube furnished by installer.)
CONNECT WATER SUPPLY LINE FROM SUPPLY STOP(S) TO SOLENOID
VALVE
Flush dirt, debris, and sediment from the supply line(s).
For Dual Line Hot and Cold Water Supply Applications
N
Noottee:: When connecting the Faucet to a hot and cold water supply, a Bak-Chek
®
Compression Tee is required as shown in Figures 1A and 7.
Install a 3/8 inch (10 mm) copper supply tube between the Bak-Chek
®
Compression Tee and the hot and cold supply stops. (Supply tubes and supply
stops furnished by installer.) Tighten Compression Fittings securely.
Install a 3/8 inch (10 mm) copper supply tube between the Bak-Chek
®
Compression Tee and the inlet side of the Solenoid Valve.
N
Noottee:: Failure to install the Bak-Chek
®
Compression Tee can result in a cross flow
connection when the faucet is in the off position and the supply stops are open.
If the pressures of the hot water supply and cold water supply are different, hot
water can migrate into the cold water supply or cold water can migrate into the
hot water supply. Most plumbing codes require that the Bak-Chek
®
be used to
prevent this.
For Single Line Water Supply Applications
N
Noottee:: When connecting the Faucet to a single line water supply or a pre-tempered
water supply, a Bak-Chek
®
is not required as shown in Figures 1A and 7.
Install a 3/8 inch (10 mm) copper supply tube between the supply stop and inlet
side of Solenoid Valve. (Supply tube and supply stop furnished by installer.)
Tighten Compression Fittings securely.
Install Spray Head into opening of Spout.
Tighten Spray Head with Key provided.
Figure 6
FLANGE NUT
1/4” (6 mm) TO 3/8” (10 mm)
COMPRESSION FITTING
3/8” (10 mm) SOLENOID
VALVE COMPRESSION
CONNECTION (TOP OUTLET)
SOLENOID VALVE
3/8” (10 mm) SOLENOID
VALVE COMPRESSION
CONNECTION (BOTTOM INLET)
3/8” BAK-CHEK
®
TEE
COMPRESSION FITTING
3/8” (10 mm) SUPPLY TUBE
(NOT SUPPLIED)
3/8” (10 mm) SUPPLY TUBE
(NOT SUPPLIED)
THREAD THE SPRAY
HEAD INTO OPENING
OF SPOUT
Figure 8
SPOUT
Figure 5
DRILL FOUR HOLES INTO WALL
USING MOUNTING FASTENERS
APPROPRIATE FOR THE
PARTICULAR WALL TYPE:
• PLASTIC WALL ANCHOR —
1/4” (6 mm) HOLE
• HOLLOW WALL ANCHOR —
5/16” (8 mm) HOLE
• TOGGLE NUT ANCHOR —
3/8” (10 mm) HOLE
3½”
(89 mm)
4
3
/
8
”
(111 mm)
PLASTIC ANCHOR
WITH SCREW AND
WASHER SHOWN
CONTROL
MODULE
3/8” (10 mm)
BAK-CHEK TEE
USED ON DUAL
WATER SUPPLY
APPLICATIONS
ONLY
HOT AND COLD
WATER SUPPLY
SINGLE LINE
WATER SUPPLY
3/8” (10 mm)
COMPRESSION
FITTING
3/8” (10 mm)
SUPPLY TUBE
SOLENOID
VALVE
SUPPLY STOP
Figure 7
Step 4 — Connect Water Supply Lines (Figures 1A, 6 and 7)
Step 5 — Install Spray Head (
Figure 8
)