3
10
9
6B
5A
Slide the Positioning Plate over the
water supply line.
POSITIONING
PLATE
Loosely attach the
Positioning Plate
directly to the wall
stud using fasteners
in the top and bottom
slots as illustrated.
POSITIONING
PLATE
7
Attach plumb line to hook.
8
Level Positioning Plate
by centering Plumb Line
with Slot and Centerline
of Drain.
When Positioning Plate is
level, snug Top Rail
Fasteners to wall studs.
When Positioning Plate is
centered with drain line,
snug Plate Fasteners.
For Applications Where Water Supply Line
and Electrical Box are Located Between Studs
(Follow Steps 4A through 6A)
For Applications Where Stud Separates
Water Supply Line and Electrical Box
(Follow Steps 4B through 6B)
Rotate the Positioning
Plate so that the electrical
box opening is opposite
the water supply line.
4A
Rotate the Positioning Plate so
that the electrical box opening is
opposite the water supply line.
4B
WATER SUPPLY
LINE
TOP
MOUNTING
RAIL
WATER SUPPLY
LINE
POSITIONING
PLATE
6A
Loosely attach the top
Mounting Rail to the two
closest wall studs as
illustrated.
5B
Slide the Positioning Plate over the
water supply line.
SLOT
PLUMB LINE
11
Install and snug
Lower Rail Fasteners
to wall studs.
12
For single stud applications,
when Positioning Plate is level
and Plumb Line is centered with
Centerline of Drain, snug top and
bottom fasteners.
11½”
ABOVE
TOP OF
FIXTURE
CENTERLINE OF DRAIN
Separate the two pipe supports using a utility knife
or scissors. Install the appropriate Pipe Support
over the water supply line and attach it to the
Positioning Plate using the Fastener provided.
Either mounting hole may be used.
13
PIPE SUPPORT
FASTENER
(SUPPLIED)
After Installation of the Sloan Optima ES-S Flushometer Electrical Box
Positioning and Support Kit
• Install the plaster ring of the required depth to the electrical box leaving the
screws loose (approximately one-half way out).
• Insert the electrical box assembly into the opening
from behind the
Positioning Plate
. The opening is designed so that the electrical box is
inserted at an angle and rotated into position. Once the electrical box is
rotated into place, firmly tighten the screws.
• Electrical wiring
• Finish wall
• Mount fixture
NNOOTTEE:: EElleeccttrriiccaall bbooxx
aanndd ppllaasstteerr rriinngg aarree
nnoott ssuupppplliieedd
WATER
SUPPLY
LINE
POSITIONING
PLATE