background image

3

10

9

6B

5A

Slide the Positioning Plate over the

water supply line.

POSITIONING

PLATE

Loosely attach the

Positioning Plate

directly to the wall

stud using fasteners

in the top and bottom

slots as illustrated.

POSITIONING

PLATE

7

Attach plumb line to hook.

8

Level Positioning Plate

by centering Plumb Line

with Slot and Centerline

of Drain.

When Positioning Plate is

level, snug Top Rail

Fasteners to wall studs.

When Positioning Plate is

centered with drain line,

snug Plate Fasteners.

For Applications Where Water Supply Line

and Electrical Box are Located Between Studs

(Follow Steps 4A through 6A)

For Applications Where Stud Separates

Water Supply Line and Electrical Box

(Follow Steps 4B through 6B)

Rotate the Positioning

Plate so that the electrical

box opening is opposite

the water supply line.

4A

Rotate the Positioning Plate so

that the electrical box opening is

opposite the water supply line.

4B

WATER SUPPLY

LINE

TOP

MOUNTING

RAIL

WATER SUPPLY

LINE

POSITIONING

PLATE

6A

Loosely attach the top

Mounting Rail to the two

closest wall studs as

illustrated.

5B

Slide the Positioning Plate over the

water supply line.

SLOT

PLUMB LINE

11

Install and snug

Lower Rail Fasteners

to wall studs.

12

For single stud applications,

when Positioning Plate is level

and Plumb Line is centered with

Centerline of Drain, snug top and

bottom fasteners.

11½”

ABOVE

TOP OF

FIXTURE

CENTERLINE OF DRAIN

Separate the two pipe supports using a utility knife

or scissors. Install the appropriate Pipe Support

over the water supply line and attach it to the

Positioning Plate using the Fastener provided.

Either mounting hole may be used.

13

PIPE SUPPORT

FASTENER

(SUPPLIED)

After Installation of the Sloan Optima ES-S Flushometer Electrical Box

Positioning and Support Kit

• Install the plaster ring of the required depth to the electrical box leaving the

screws loose (approximately one-half way out).

• Insert the electrical box assembly into the opening 

from behind the

Positioning Plate

. The opening is designed so that the electrical box is

inserted at an angle and rotated into position. Once the electrical box is

rotated into place, firmly tighten the screws.

• Electrical wiring
• Finish wall
• Mount fixture

NNOOTTEE:: EElleeccttrriiccaall bbooxx

aanndd ppllaasstteerr rriinngg aarree

nnoott ssuupppplliieedd

WATER

SUPPLY

LINE

POSITIONING

PLATE

Отзывы: