Note:

Tabo outdoor station can be powered by12V power supply or by PoE (802.3af)

 

through LAN connector.

Note:

Total network cable length between devices must not exceed 80 meters for PoE connection (red) and 100  
meters for ordinary connection ()without PoE.

Diagram 2. Basic network connection

4. Installation

4.1 Schematic diagrams

Diagram 1. Tabo mechanical lock connection

Internet
connection

Tabo

5

6

Mechanical

lock

Lock power

supply

COM

NO

Magnetic

lock

Lock power

supply

NC

COM

Exit

GND

Open lock

button

Diagram 2. Tabo electromagnetic lock connection

Power supply

12V, 2A

+12V GND

+12V GND

Imani indoor monitor

Tabo outdoor station

Router 
with PoE

WAN                   1                 2                 3                 4

CAT5 twisted pair cable

CAT5 twisted pair cable
with PoE

Содержание Tabo

Страница 1: ...Tabo Design Uniqueness Innovations Design Uniqueness Innovations User manual Technicalsupport Thank you for choosing our equipment IP video outdoor station PoE function 720P 1 Mp...

Страница 2: ...re range Installation surface should be free from vibration and impact influence Keep this device far from open sources of heat such as radiators heaters and ovens The device can be installed near oth...

Страница 3: ...m 4 01 29 mm 1 14 Tabo 3 4 SENSOR 1 4 CMOS RESOLUTION 720p 1280x720 H 264 Main Profile HORIZONTAL VIEW ANGLE 100 LOCK RELAY CONTINUOUS CURRENT 10 A BACKLIGHT TYPE White LED s 6pcs POWER DC 12 V or PoE...

Страница 4: ...m 2 Basic network connection 4 Installation 4 1 Schematic diagrams Diagram 1 Tabo mechanical lock connection Internet connection Tabo 5 6 Mechanical lock Lock power supply COM NO Magnetic lock Lock po...

Страница 5: ...mount Rainshield mount 5 Software setup Door station default IP address is 192 168 1 90 or 192 168 1 91 Enter this IP adress into PC s browser address line to enter web interface Note that your PC mus...

Страница 6: ...evice mode can be only Personal for this outdoor station Building building number Unit unit number Floor floor number Apartment apartment number Device number if there are several outdoor panels then...

Страница 7: ...on the left side of the screen to enter access management settings Access management Master card master card number if panel has wireless ID reader Use master code enable disable master code Master co...

Страница 8: ...ng Add button If the first number doesn t answers during 20 seconds then the call forwards to the second one and so on 5 5 Advanced settings Press Advanced bookmark on the left side of the screen to e...

Страница 9: ...ken the product was not used for its intended function This limited warranty covers only repair replacement refund or credit for defective products as provided above Manufacturer is not liable for and...

Отзывы: