background image

 

3.

 

Remote Control 

The  air  conditioner  can be  controlled via  a  remote  control. Two AAA-batteries are  required to use  the  remote 
control.   
Note: the air flow direction cannot be adjusted with the remote control. 

1. Power: Press the 

  key to turn on or turn off the machine 

2. Timer: Press the 

  key to set the timer 

3. Down: Press the 

  key to decrease temperature and timer 

4. Mode: Press the 

  key to switch between cooling, fan, dehumidifier   

5. Up: Press the 

  key to increase temperature and timer 

6. Fan: Press the 

  key to select high / low fan speed 

7. Sleep Mode: Press the 

  key to turn on the sleep mode 

 
 
 

Multi protective function   

4.1.

 

Frost Protection Function: In cooling, dehumidification or economic power saving mode, if the 

temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if 
the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to 
normal operation.

 

4.2.

 

Overflow Protection Function: When the water in the internal water tank exceeds the warning 

level, the machine will automatically sound an alarm, and the LCD temperature display area will show 
"FL". At this point, you need to move the drainage pipe connecting the machine or the water outlet to 
sewer, other drainage area or a flat tray to empty the water (details see Drainage Instructions at the 
end of this chapter). After the water is emptied, the machine will automatically return to the original 
state. 

 

4.3.

 

Automatic Defrosting (cooling models have this function):    The machine has automatic 

defrosting function: during defrosting, heating symbol on the display screen will flash.

 

4.4.

 

Automatic Thermal Protection:    To protect the service life of the machine, the machine has 

automatic thermal protection in heating mode. During the protection period, the compressor and the 
lower motor will stop operation and will automatically return to normal heating state after the 
temperature of the machine recovers.

 

4.5.

 

Protection Function of the Compressor: To increase the service life of the compressor, it has a 3-

minute delay start protection function

 

EMPTYING THE WATER CONTAINER

 

1.

 

Manual drainage:   

1.1

 

When the internal water tank is full the unit will stop working.     

1.2

 

Shut off the unit and unplug. Try not to move the model abruptly as this may cause water to 
may cause the internal water tank to spill out.   

Содержание CLIM9000CE

Страница 1: ...CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference...

Страница 2: ...supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard Any service other than regular cleaning or filter replacement should be performed by an author...

Страница 3: ...g Cap 12 Power supply cord Installation Warning Before using this unit please keep it upright for at least 3 4 hours This unit can easily be moved from one room to another While moving the unit please...

Страница 4: ...s and outlet grills 6 Fix the other end of the hose to the air outlet window kit Note The window kit is only designed to be installed with sliding or sash windows or doors The window kit is not design...

Страница 5: ...is length the unit may malfunction and this can invalidate the warranty The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat Avoid bending the air hose mo...

Страница 6: ...s Castors and handles for portability Compressor protection technology for extended life span 2 OPERATION Selection Keys and Display Indicator LED 1 Power On Off 9 Tank Full indicator light 2 Mode Sel...

Страница 7: ...ss TIMER to adjust the timer from 1 to 24 hours Timer indicator turns on Unit will start after selected number of hours Under power on mode press TIMER to setup power off timer Press TIMER to adjust t...

Страница 8: ...an alarm and the LCD temperature display area will show FL At this point you need to move the drainage pipe connecting the machine or the water outlet to sewer other drainage area or a flat tray to e...

Страница 9: ...vaporated Please do not use continuous drainage if you intend to use the self evaporating facility Maintenance Cleaning Please shut off the unit and unplug from the mains before cleaning or performing...

Страница 10: ...e it as directed in this user manual and only perform operations advised here Problems Reasons Solutions The air conditioning does not work There is no electricity Turn it on after connecting it to a...

Страница 11: ...eatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to parti...

Страница 12: ...rm 1 Has the unit been standing upright for at least 2 hours 2 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restar...

Отзывы: