S-link Planning & Precautions
S-link is a ”CAN” based control system with full intelligent communication between all units in the system.
Main advantages include:
- Round, compact and waterproof plugs with unique keying and colour coding to avoid faulty hookup.
- An unlimited number of commands or information transfer on a single cable.
- Proprietary Sleipner commands but built 100% on NMEA 2000 standard.
Routing the Backbone:
Keep routing backbone spur cables to a minimum. Avoid routing the S-link cables close to equipment that might cause interference to the S-link
signals such as radio transmitter equipment, antennas or high voltage cables. The backbone MUST be terminated at each end with the 6 1327 End
Terminator.
Spur cables:
Spur cables can be left not terminated
(NB: Routing can be prepared for future additional equipment)
. Make sure to protect open connectors from
water and moisture to avoid corrosion in the connectors.
MG_0159
S1=_____
BB1=___
BB2=___
S2=_____
Positive, Negative
& Shield
Example of the control wiring
with S-link system for boats
with one control position and
one thruster.
Bow Thruster
Automatic
Main switch
BACKBONE Cable
Forms the main
“loop” around the
boat.
SPUR Cable
Must be used to connect all
parts to the backbone cable
(One for each component, no
exceptions). Recommended to
be as short as practically
possible.
POWER Cable
Must be one in each
system, length 2.5m
4-Port T Connector
The 4-port T-connector allows multiple spur cables to be
connected.
(NB: Comes with two sealing caps to protect.)
T- Connector
Must be one for each spur,
including power cable
BACKBONE extender
Connects two BACKBONE
cables to extend length.
END terminator
Must be one for each end
of the BACKBONE “loop”.
Power Supply
Control Panel
You need:
2 x 6 1327 End terminators
3 x 6 1326 T-connectors
1 x 6 1328 Power spur
2 x 6 1320-xxM Backbone cables
2 x 6 1321-xxM Spur cables
Thruster
Control Panel
Backbone cables
Forms the main ”loop” around the boat
Part #: 6 1320-xxM (xx=length)
0,2 m
2,0 m
4,0 m
7,0 m
15,0 m
20,0 m
Spur cables
Must be used to connect all parts to the backbone cable (one for each component, no
exeptions), recommended to be as short as practically possible
Part #: 6 1321-xxM (xx=length)
0,4 m
1,0 m
3,0 m
5,0 m
Power cable (spur)
Must be one in each system,
delivered in the length of 2,5m
Part #: 6 1328
T-connector
Must be one for each spur,
including the power cable
Part #: 6 1326
End terminator
Must be one in each end
of the backbone ”loop”
Part #: 6 1327
S-link cable parts
Control
panel
Power
supply
Automatic
mainswitch
Bow
thruster
Example of wiring
Wiring of S-link system
Explaining S-link
S-link is a ”CanBus” based control system
with full intelligent communication
between all units in the system, much like
a computer network.
Main advantages include:
-
Round, compact and waterproof plugs with
unique keying to avoid faulty hookup
-
Unlimited number of commands or information
transfer on a single cable
-
Proprietary Sleipner commands, but built 100%
on NMEA 2000 standard
Control Panel Installation
Find a suitable location for the control panel where it does not obstruct or is obstructed by other devices. Install the control panel on a flat surface
where it is easy to use.
1. Use the supplied cut-out template to mark the area to remove on your control dash.
2. Cut out the area per template for the control panel. (
NB: If the front surface around your cut out is jagged or chipped, use a sealant
to assist the gasket.)
3. Place the gasket to the back face of the panel
4. Plug cables into the connectors at the rear of the control panel.
5. Insert the control panel in place and fasten screws.
6. Insert the control panels covering caps.
MC_0042
!
Please refer to the graphic for special considerations relating to your model
!
MG_0063
GASKET
4x SCREWS
58 mm
67 mm
125 mm
116 mm
132.7 mm
75.7 mm
Ø 4.5 mm
Ø 4.5 mm
Ø 4.5 mm
Ø 4.5 mm
(S-link)
External alarm buzzer
12V / 24V DC - max 0,5A
External alarm / buzzer connection
Supply
+ 12V / 24V DC
-
+
Ø 4.5 mm
Rear
side
of pa
nel
Internal
fuse / relay