Sleipner SXP35 Скачать руководство пользователя страница 21

 21

5926

19

2021

-

SXP35 & SXP50

MC_0120

S-link Planning & Precautions

S-link is a ”CAN” based control system with full intelligent communication between all units in the system. 

Main advantages include:

- Round, compact and waterproof plugs with unique keying and colour coding to avoid faulty hookup.

- An unlimited number of commands or information transfer on a single cable.

- Proprietary Sleipner commands but built 100% on NMEA 2000 standard.

Routing the Backbone:

Keep routing backbone spur cables to a minimum. Avoid routing the S-link cables close to equipment that might cause interference to the S-link 

signals such as radio transmitter equipment, antennas or high voltage cables. The backbone MUST be terminated at each end with the 6 1327 End

Terminator.

Spur cables:

Spur cables can be left not terminated 

(NB: Routing can be prepared for future additional equipment)

. Make sure to protect open connectors from

water and moisture to avoid corrosion in the connectors.

MG_0159

S1=_____

BB1=___

BB2=___

S2=_____

Positive, Negative 

& Shield

Example of the control wiring 

with  S-link system for boats 

with one control position and 

one thruster. 

Bow Thruster

Automatic 

Main switch

BACKBONE Cable

Forms the main 

“loop” around the 

boat.

SPUR Cable

Must be used to connect all 

parts to the backbone cable 

(One for each component, no 

exceptions). Recommended to 

be as short as practically 

possible.  

POWER Cable

Must be one in each 

system, length 2.5m

4-Port T Connector

The 4-port T-connector allows multiple spur cables to be 

connected. 

(NB: Comes with two sealing caps to protect.)

T- Connector

Must be one for each spur, 

including power cable 

BACKBONE extender

Connects two BACKBONE 

cables to extend length.

END terminator

Must be one for each end 

of the BACKBONE “loop”.

Power Supply

Control Panel

You need:

2 x 6 1327 End terminators

3 x 6 1326  T-connectors

1 x 6 1328 Power spur

2 x 6 1320-xxM Backbone cables

2 x 6 1321-xxM  Spur cables

Thruster

Control Panel

Backbone cables

Forms the main ”loop” around the boat

Part #: 6 1320-xxM (xx=length)

0,2 m

2,0 m

4,0 m

7,0 m

15,0 m

20,0 m

Spur cables

Must be used to connect all parts to the backbone cable (one for each component, no 

exeptions), recommended to be as short as practically possible

Part #: 6 1321-xxM (xx=length)

0,4 m

1,0 m

3,0 m
5,0 m

Power cable (spur)

Must be one in each system,

delivered in the length of 2,5m

Part #: 6 1328

T-connector

Must be one for each spur,

including the power cable

Part #: 6 1326

End terminator

Must be one in each end 

of the backbone ”loop”
Part #: 6 1327

S-link cable parts

Control

panel

Power 

supply

Automatic

mainswitch

Bow

thruster

Example of wiring

Wiring of S-link system 

Explaining S-link

S-link is a ”CanBus” based control system

with full intelligent communication

between all units in the system, much like

a computer network.

Main advantages include:

-

Round, compact and waterproof plugs with 

unique keying to avoid faulty hookup

-

Unlimited number of commands or information 

transfer on a single cable

-

Proprietary Sleipner commands, but built 100% 

on NMEA 2000 standard

Control Panel Installation 

Find a suitable location for the control panel where it does not obstruct or is obstructed by other devices. Install the control panel on a flat surface 

where it is easy to use. 

1.  Use the supplied cut-out template to mark the area to remove on your control dash. 

2.  Cut out the area per template for the control panel. (

NB: If the front surface around your cut out is jagged or chipped, use a sealant

to assist the gasket.)

3.  Place the gasket to the back face of the panel 

4.  Plug cables into the connectors at the rear of the control panel. 

5.  Insert the control panel in place and fasten screws.

6.  Insert the control panels covering caps.

MC_0042

!

 Please refer to the graphic for special considerations relating to your model 

!

MG_0063

GASKET   

4x SCREWS 

58 mm

67 mm

125 mm

116 mm

132.7 mm

75.7 mm

Ø 4.5 mm

Ø 4.5 mm

Ø 4.5 mm

Ø 4.5 mm

(S-link)

External alarm buzzer

12V / 24V DC - max 0,5A

External alarm / buzzer connection

Supply

+ 12V / 24V DC 

-

+

Ø 4.5 mm

Rear

side

of pa

nel

Internal

fuse / relay

Содержание SXP35

Страница 1: ...LEIPNER AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE Installation Guide For Pro DC External Electric Thruster Models SXP35 SXP50 EN I M 5926 19 202...

Страница 2: ...he Stern Thruster 7 Stern Thruster Cowls Grids 8 Thruster Installation Instructions Thruster Installation Considerations and Precautions 10 Grids or Cowls Assembly 11 Tunnel Installation 12 Motor Inst...

Страница 3: ...ide the boat like steerage links etc NB It is possible to mount the tunnel offset from the boat s centre line if necessary Heat protection cut off is calculated from the thruster motor To avoid cable...

Страница 4: ...nch H Motor Height 374 14 72 374 14 72 W Width 183 7 20 183 7 20 L Length 171 6 7 171 6 7 L Standard tube length 108 4 3 108 4 3 L Extended tube length for thicker hulls 276 10 9 276 10 9 a Height of...

Страница 5: ...lapse device protects against sudden change of drive direction The electric thermal cut off switch in electro motor protects against overheating auto reset when electro motor cools down Original Slei...

Страница 6: ...SX35 SX50 Operation volts 12v 12v Max Current 250A 380A Duty Cycle S2 S2 Max ambient temp 50 c 50 c Min ambient temp 25 c 25 c Power supply cable 35 70mm AWG 2 00 35 70mm AWG 2 00 Mount direction Any...

Страница 7: ...turb the water flow under the hull At higher speeds if the thruster is installed to low can cause damage to the thruster additional drag and unwanted water splashing Alignment The thruster can be inst...

Страница 8: ...ooth inner walls for optimal water flow and strength A standard Sidepower stern thruster tunnel with add on cowls for shallow installation cowls to change the water flow direction to avoid obstruction...

Страница 9: ...e thruster Ensure there is enough space both inside and outside the transom of the boat and the thruster does not get in conflict with existing equipment inside the boat like steerage links etc NB It...

Страница 10: ...074 Grids or Cowls assembly 1 Attach the cowls or grids with included bolts and washers NB If installion of the cowls ensure the appropriate twist of the cowl to direct water away from obstacles MG_01...

Страница 11: ...2 Tunnel Installation 1 Ensure to remove the plasic cover guard on the tunnel 2 Connect both ends of the tunnel to the thruster motor All hooks must be completely interlocked making the inside of the...

Страница 12: ...ttaching the spacer as the top support holes are larger than the spacers 4 Drill out the two support bolt holes in the spacer 5 Apply MS Polymer sealant or equal to the back surface face of the spacer...

Страница 13: ...lly place the thruster through the holes to ensure correct fitting Using the cable leads from the thruster define the location within the vessel for the installation of the control box NB If using a s...

Страница 14: ...nal slot in the propeller 2 Insert the washer to the end of the shaft spline Tighten with the propeller lock nut 3 Apply anti fouling to the gear leg and propeller Do not apply anti fouling to any rub...

Страница 15: ...nd drill the holes 3 Attach cables to the control box NB the control box internal components can be removed via its attachment screws for easier installation using thick battery cables 4 Tighten hose...

Страница 16: ...the electrical operation of the vessel when not on board or in emergencies NB It is advised to install a fuse on the positive cable for protection against short circuiting of the main cables The fuse...

Страница 17: ...1 Thruster A2 Temp switch NC NTC Temp switch NC NTC BLUE HOSE SX50 CONTROL BOX SX35 CONTROL BOX B B Tighten to 5 6 NM 4 13 lb ft Blue Hose Blue Hose Tighten to 5 NM 3 69 lb ft Tighten to 5 NM 3 69 lb...

Страница 18: ...0 2 x 2 0 35 140 12 V 245 A DIN 200 SAE 380 EN 330 ANL 150 mm2 35 50 50 70 70 95 95 120 120 2 x 70 2 x 70 2 x 95 AWG 2 1 0 1 0 2 0 2 0 3 0 3 0 4 0 4 0 2 x 2 0 2 x 2 0 2 x 3 0 50 1400 12 V 370 A DIN 3...

Страница 19: ...play and require no additional configuration setup See the Control panel manual for more information MC_0041 Please refer to the graphic for special considerations relating to your model MG_0127 Autom...

Страница 20: ...as short as practically possible POWER Cable Must be one in each system length 2 5m 4 Port T Connector The 4 port T connector allows multiple spur cables to be connected NB Comes with two sealing caps...

Страница 21: ...cut out is jagged or chipped use a sealant to assist the gasket 3 Place the gasket to the back face of the panel 4 Plug cables into the connectors at the rear of the control panel 5 Insert the contro...

Страница 22: ...n switch size No water leakage around hull penetrated studs Check that there is no electrical connection between the electro motor body and positive terminal on the motor and between the electro motor...

Страница 23: ...ed to the Purchaser at the Warrantor s expense If on the other hand the claim is determined to result from circumstances such as described in section 4 above or a result of wear and tear exceeding tha...

Страница 24: ...ccuracies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Motor AS can not accept liability for any possible differen...

Отзывы: