15
6398
12
2022
-
HydroPOD 35 & 50
Control Box Installation
Follow the below steps to install the Control Box. Additional installation details can be found in the corresponding graphics.
1. Pull the blue SX Thruster Hose around the cable harness coming out of the SX Thruster. Fasten the hose clamp.
2. Defi ne the location to install the Control Box. It can be mounted in any orientation, preferably with cables facing down. The control box must be
positioned within 0.75 meters from the thruster attachment bolts. Ensure that the SX Thruster Hose will not obstruct any objects and not placed
near any object that radiate high temperatures.
3. Mark the locations of the four drill holes and drill the holes. Ensure that the back wall where the Control Box is to be mounted have suffi cient
thickness and strength.
MC_0075
MG_0530
Control box
installation
location
SX thruster
hose
Max 0.75m
1
2
3
Hose claps
MG_0114
B-
B+
SX50
CONTROL BOX
SX35
CONTROL BOX
4
Tighten to
8 - 9.5 NM
6 - 7 ft/lb
Temp
switch NC
NTC
A1
A2
Control Box
hose clamp
B / - cable
A1 / A2 cable
SX/P 35 does not come with
a control box cover
6
5
B / - cable
Tighten to
3.6 - 3.9 NM
2.7 - 2.9 ft/lb
Tighten to
3.6 - 3.9 NM
2.7 - 2.9 ft/lb
NTC
Temp
switch NC
A1
A2
Control Box Installation
4. Follow the cable marking and fasten motor power cables coming from the SX Thruster in the control box. The motor power cables are marked
A1 and A2 and should be fastened to the terminal with corresponding marking. Place the ring cable lug connected to the white wire between the
lug of the motor power cable and the nut. Fasten the nut with recommended torque. Ensure that the ring cable lug is kept at same terminal as
originally placed.
- Insert the B+ and M- power cables into the grommet or external connectors as shown in fi gure below. Fasten the power cables to the terminals
with recommended torque.
- Connect the Temp Switch and NTC connector
5. Tighten hose clamp on Control Box.
6. Fasten the control box to the hull.
MC_0075
IMPORTANT
It is the installers full responsibility to follow instructions and ensure total Ignition Protection.