HydroPOD 35 & 50
MC_0074
Grids or Cowls assembly
1. Attach the cowls or grids with included bolts.
(NB: If installation of the cowls ensure the appropriate twist of the cowl to direct water away from
obstacles)
MG_0145
*Cowl
*Grid
Grids and cowls can not be installed in
combination. Only one option is possible
at a time.
Tighten 2Nm
Correct rotation of the grid/ cowl requires the longer
spaced bolts at the top and the shorter spaced bolts at
the bottom
Electrical Reference
Guide
MC_0077
Model Size
System
Voltage
Nominal
current
draw
Min. battery
CCA
Rec.
fuse
Cross Section Guide for Power Cables
Unit
<7m
total + & -
7-14m
total + & -
15-21m
total + & -
22-28m
total + & -
28-35m
total + & -
36-45m
total + & -
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
35/140
12V
245 A
DIN: 200
SAE: 380
EN: 330
ANL 150
mm²
35
50
50
70
70
95
95
120
120
2 x 70
2 x 70
2 x 95
AWG
2
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2 x 2/0
2 x 2/0
2 x 3/0
50/140S
12V
370 A
DIN: 350
SAE: 665
EN: 600
ANL 325
mm²
50
50
70
95
120
2 x 70
2 x 70
2 x 95
2 x 95
2 x 120
2 x 120
2 x 120
AWG
1/0
1/0
2/0
3/0
4/0
2 x 2/0
2 x 2/0
2 x 3/0
2 x 3/0
2 x 4/0
2 x 4/0
2 x 4/0