19
5630
22
2021
-
SX35 & SX50
Electrical Specifi cations
MC_0077
Model Size
System Voltage
Nominal current
draw
Min. battery
CCA
Rec. fuse
<7m total + & -
7-14m total + & -
15-21m total + & -
22-28m total + & -
28-35m total + & -
36-45m total + & -
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
AW
G
3
2
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2 x 2/0
2 x 2/0
*35/140
12 V
245 A
DIN: 200 SAE: 380 EN: 330
ANL
150
mm2
35
50
50
70
70
95
95
120
120
2 x 70
2 x 70
2 x 95
AW
G
2
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2 x 2/0
2 x 2/0
2 x 3/0
*50/1400
12 V
370 A
DIN: 350 SAE: 665 EN: 600
ANL
325
mm2
50
50
70
95
120
2 x 70
2 x 70
2 x 95
2 x 95
2 x 120
2 x 120
2 x 120
AW
G
1/0
1/0
2/0
3/0
4/0
2 x 2/0
2 x 2/0
2 x 3/0
2 x 3/0
2 x 4/0
2 x 4/0
2 x 4/0
24 V
170 A
DIN: 175 SAE :332 EN: 280
ANL
150
mm2
25
25
25
35
35
50
35
50
50
70
70
70
AW
G
3
3
3
2
2
1/0
2
1/0
1/0
2/0
2/0
2/0
Control Panel Cable Installation
•
All Sleipner control panels can be used in any combination.
•
All control panels can be installed using:
• Y-connectors - for standard on/off
• T-connectors - for S-Link proportional power system.
(NB: If two or more control panels are operated at the same time in opposite directions, the electronic control box will stop the thruster until
it receives a single signal or thrust in one direction.)
•
Sleipner on/off equipment it is entirely “plug & play” and require no additional confi guration setup.
See the Control panel manual for more information.
MC_0041
!
Please refer to the graphic for special considerations relating to your model
!
MG_0115
Thruster
Motor
Automatic Main switch
Manual Main switch
Ext. cable
5-lead
Y cable
5-lead
* 5 LEAD EXTENSION
CABLES
* 4 OR 5 LEAD EXTENSION
CABLES
Ext. cable
5-lead
Thruster
Motor
Ext. cable
4- or 5-lead
Y cable
4- or 5-lead
Ext. cable
4- or 5-lead
Option: Automatic main switch. connects the battery to
the thruster. Operated from the control panel(s).
Requires 5-lead control cables.