background image

 
                                                                                     

 

 

  1. SAFETY INSTRUCTION   

     

 

WARNING 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure 

that they also receive this instruction booklet. 

 

 

 

Caution: 

 

All fixtures are intact from the manufacturer, please operate follow up the user manual, artificial 

fault are not under guarantee repair. 

 

Unpack and check carefully that there is no transportation damage before using the unit per first 

time. 

 

DO install and operate by operator. 

 

Use safety chain when fixes the unit. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 

surfaces.   

 

Before  operating,  ensure  that  the  voltage  and  frequency  of  power  supply  match  the  power 

requirements of the unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature Ta: 40°C. DO NOT operate it where the temperature is higher 

than this. 

 

DO NOT connect the device to any dimmer pack. 

 

Make  sure  there  are  no  flammable  materials  close  to  the  unit  while  operating,  as  it  is  fire 

hazard. 

 

Look over power wires carefully, replace immediately if there is any damage. 

 

Unit surface temperature may reach up to 60°C. DO NOT touch the housing bare-hand during 

its operation. 

 

Please read the instructions carefully which includes important 
information about the installation, operation and maintenance. 

Содержание AEDI WASH GLOBUS 90 RGBW

Страница 1: ...AEDI WASH GLOBUS 90 RGBW User Manual Please read the instructions carefully before use Version 1 0 ...

Страница 2: ...CAL SPECIFICATIONS 4 4 ACCESSORIES 5 5 HOW TO SET THE FIXTURE 6 5 1 CONTROL PANEL 6 5 2 MAIN FUNCTIONS 7 6 HOW TO CONTROL THE UNIT 13 6 1 DMX controller 13 6 2 DMX 512 configuration 15 7 DMX512 CONNECTIONS 16 8 TROUBLESHOOTING 17 9 FIXTURE CLEANING AND MAINTANCE 18 ...

Страница 3: ...0cm from adjacent surfaces Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature Ta 40 C DO NOT operate it where the temperature is higher than this DO NOT connect the device to any dimmer pack Make sure there are no fla...

Страница 4: ... manufacturer does not take responsibility if the device is operated under conditions other than described in this manual The product may suffer damage and the guarantee becomes void Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are ...

Страница 5: ...SPECIFICATIONS OMS R D specialists have designed this fixture to replace the traditional outdoor 400W discharge fixtures Proper thermal management with active cooling system and heavy duty design to ensure reliable performance under harsh environment It features 90pcsx3W CREE RGBW LEDs provides powerful output and excellent color mixing Great built in programs for instant light shows Different opt...

Страница 6: ... DMX 512 A Power Consumption Max 267 W Average consumption in color mixing mode 140 W Power cable connection IP rated connectors Service lifetime 50 000 hrs L70 25 C Operating ambient tem 20 C 40 C Materials Housing die cast aluminum Cover clear hardened glass IP Rating IP66 Dimension 399 400 195mm Weight 16 4 kg Finishing White aluminum RAL 9006 Accessories DMX controllers AEDITEMPAATTACA AEDITEM...

Страница 7: ...o go backward in the selected functions 4 UP To go forward in the selected functions 5 ENTER To confirm the selected functions 6 POWER IN Water proof connectors for power input 7 POWER OUT Water proof connectors for power output 8 DMX IN Water proof 3 pin XLR connectors for DMX 512 operation 9 DMX OUT Water proof connectors for DMX 512 operation with 3 pin XLR plug ...

Страница 8: ...NTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press the MENU button The main functions are shown below Once you set to after running in show mode for 5 minutes without any change or restarting the unit the key board become locked Press the ENTER button to enable the menu the display wil...

Страница 9: ...8 ...

Страница 10: ...t among the built in programs Select the press the ENTER button and the display will blink Use the DOWN and UP button to select the show 1 show 19 Once select press the ENTER button to setup press the ENTER button will blinking on the display use DOWN and UP button adjust the fade time 0 255 press the ENTER button to store and will blinking on the display use the DOWN and UP button adjust the whit...

Страница 11: ...ons without any change press the MENU button Manual Mode Press the MENU button up to when the is shown on the display Press the ENTER button and the display will blink Use the DOWN and UP button to select the Red Green Blue White Dimmer or Strobe Once selected press the ENTER button to setup then use the DOWN and UP button to adjust the value 0 255 or automatically exit menu mode without any chang...

Страница 12: ...ade press the ENTER button to confirm then use the DOWN and UP button to adjust the dimmer 1 9 Notice If flash mode is selected press the ENTER button to confirm then use the DOWN and UP button to select the wait time or shutter Once select press the ENTER button to confirm then use the DOWN and UP button to adjust the the wait time or shutter speed solw midum fast 1 9 Once select press the ENTER ...

Страница 13: ...k Press the MENU button up to when the is showing on the display Pressing the ENTER button and the display will blink Use the DOWN and UP button to select the lock the key board or normal Once select press the ENTER button to setup or automatically return to the main functions without any change after one minute Back to the previous functions press the MENU button Auto Test Press the MENU button u...

Страница 14: ...o back to the functions press the MENU button again 6 HOW TO CONTROL THE UNIT You can operate the unit by DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be affected at once Every time you turn the unit on it will show on the display After that the unit will be ready to receive DMX signal or run the built in programs 6 1 DMX Controller Us...

Страница 15: ...ing or storing automatically 8 seconds later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units ...

Страница 16: ...15 6 2 DMX 512 Configuration 4 5 7 Channels Mode ...

Страница 17: ... or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 5 Th...

Страница 18: ...ction of power Incorrect mains voltage Measure the mains voltage on the main connector The unit does not respond properly to the DMX control Incorrect DMX cable connection Check DMX connectors and cables to see if link properly Repair or replace damaged wires Incorrect address assignment to the units Check the addresses of the units and the protocol settings Unfinished data connection Insert a ter...

Страница 19: ... the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Version 1 0 Specifications are subject to change without notice ...

Страница 20: ...c Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements WWW SLEPROJECTS COM 2014 All specifications subject to change without notice ...

Отзывы: