Содержание INTREPID TRDV Series

Страница 1: ...In addition where required by the authority having jurisdiction the installation must conform to American Society of Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically...

Страница 2: ...ted within the area to be heated the boiler may be selected on the basis of gross D O E capacity output The net AHRI output ratings shown are based on an allowance for piping and pickup of 1 15 water...

Страница 3: ...ion should not be mounted directly above or within 3 ft horizontally from an oil tank vent VENT PIPING A The vent piping minimum bend radius is 12 B Place metal strapping every 36 to support vent pipe...

Страница 4: ...4 INTREPID TRDV...

Страница 5: ...ansion tank and air scoop should be located near the pump suction See Figure 4 Alternate Pump Location PIPING TANKLESS HEATER if used I Heater capacities are listed on page 2 II Pipe the built in tank...

Страница 6: ...DO NOT FIRE into an empty boiler B Be prepared to heat raw water to at least 180 F as soon as it is introduced into the boiler This procedure will remove dissolved corrosive gases C Provide drain line...

Страница 7: ...INTREPID TRDV 7 SEE Adjusting Settings Error Codes for L7224C L7248L on page 8 See page 8 for other Primaries...

Страница 8: ...everting to default settings or has stopped running the Outdoor Reset algorithms The warnings are cleared when the issue s is resolved b To clear Err 8 condition depress and hold all three user keys s...

Страница 9: ...INTREPID TRDV 9 Basic Module Wiring less circulator...

Страница 10: ...nto Combustion Chamber TURBULATOR SETTING 1 Loosen nut 1 then turn the screw 2 until the index marker 3 is aligned with the correct index number 2 Retighten the retaining nut 1 The numbers on the cast...

Страница 11: ...lockwise indicator to increase combustion air turn the screw clockwise indicator to decrease combustion air 3 The final position of the air damper will vary on each installation Use instruments to est...

Страница 12: ...kwise the burner head will move inside the blast tube AWAY from the end cone This achieves lower firing rates Similarly by turning the head adjustment screw counter clock wise the burner head will mov...

Страница 13: ...with neutral mineral oil 9 Close main cast iron burner door door on which burner is mounted Make sure that the entire seal fiberglass rope is making good contact with the boiler casting when replacin...

Страница 14: ...14 INTREPID TRDV Notes...

Страница 15: ...INTREPID TRDV 15 Notes...

Страница 16: ...SLANT FIN CORPORATION Greenvale N Y 11548 Phone 516 484 2600 FAX 516 484 5921 Canada Slant Fin LTD LTEE Mississauga Ontario www slantfin com Copyright 2011...