background image

4

Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com

Rev. 0.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 5, 2021

3.  ClockBuilder Desktop Software Installation

The following sections describe how to install and begin using the software. There is also a readme.txt file with the
installation files as well as a user guide installed with the software.

3.1.  System Requirements

Microsoft Windows 2000 or Windows XP

USB 2.0

2 MB of free hard drive space

1024 x 768 screen resolution or greater

Microsoft .NET Framework 1.1 

USBXpress 3.1.1 driver

Note:

USBXpress 3.1.1 driver is provided and installed with the software. Newer or older versions of USBXpress available
from other EVB kits or online have not been tested with this software.

3.2.  Microsoft .NET Framework Installation

The Microsoft .NET Framework is required before installing and running the software. Details and installation
information about the .NET Framework are available via a shortcut in the NETFramework directory or at the
following web site:

http://www.microsoft.com/downloads/details.aspx?FamilyId=262D25E3-F589-4842-8157-
034D1E7CF3A3&displaylang=en

There are multiple versions of the .NET Framework available from Microsoft, and they can be installed side-by-side
on the same computer. The software requires version 1.1. Contact your system administrator for more details.

3.3.  ClockBuilder Desktop Software Installation

The ClockBuilder Desktop Software is installed from the ClockBuilderDesktopSwInstall.exe file.

1. Double-click the install file to start the wizard.

2. Follow the wizard instructions to complete the installation for both the software and the driver. Use the default 

installation location for best results.

3. After the installation is complete, click on 

Start

 

 

Programs

 

 

Silicon Laboratories

 

 

ClockBuilder 

Desktop Software

. Select one of the items in the menu including the User Guide to get more details on how to 

run the software.

Содержание Si5356

Страница 1: ...z quad frequency 8 output clock generator EVB Features Fully powered from a single USB port On board 25 MHz XTAL allows standalone asynchronous operation GUI programmable VDD supply allows device to operate from 3 3 V 2 5 V or 1 8 V core GUI programmable VDDO supplies allows each of the four banks of outputs to have its own supply voltage selectable from 3 3 V 2 5 V and 1 8 V GUI controlled voltag...

Страница 2: ...n controls the voltage regulators monitors the INTR pin and controls the three status LEDs There are five programmable voltage regulators VDD VDDOA VDDOB VDDOC VDDOD which supply power to the Si5356 device VDD and VDDO jumpers allow the option of powering the device from external supplies or as a convenient point for measuring current I2 C jumpers allow disconnecting the Si5356 from the I2 C bus t...

Страница 3: ... swings below ground level 2 2 2 On board XTAL The on board 25 MHz allows the Si5356 EVB to generate asynchronous clocks To use this option select the XTAL input from the Si5356 ClockBuilder Desktop software 2 3 Outputs CLK0 CLK7 Each of the eight output clocks can be accessed using SMA connectors The outputs are dc coupled no in line dc blocking capacitors between the output pin and the SMA conne...

Страница 4: ...amework is required before installing and running the software Details and installation information about the NET Framework are available via a shortcut in the NETFramework directory or at the following web site http www microsoft com downloads details aspx FamilyId 262D25E3 F589 4842 8157 034D1E7CF3A3 displaylang en There are multiple versions of the NET Framework available from Microsoft and the...

Страница 5: ...021 3 4 ClockBuilder Desktop Software Uninstall Instructions Close all the programs and help files before running the uninstaller to ensure complete removal of the software The driver software must be uninstalled separately See 3 6 USBXpress Driver Installation for details To uninstall the software use the Add and Remove Programs utility in the Control Panel as shown in Figure 3 Figure 3 Uninstall...

Страница 6: ...iles and the EVB will not work with the software Figure 4 Driver Installer Dialog Note If the driver has already been installed on the computer before it will not be reinstalled and a message box will appear as shown in Figure 5 Figure 5 Driver Already Installed The installer will copy the necessary driver files and update the operating system However for every different EVB connected to the same ...

Страница 7: ...76 3000 Fax 781 376 3100 sales skyworksinc com www skyworksinc com 7 Rev 0 2 Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice November 5 2021 Figure 6 Successful Driver Installation ...

Страница 8: ...ed via the Add and Remove Programs utility in the Control Panel Locate the entry called Silicon Laboratories USBXpress Device Click the button and it should show the version and location of what it will remove Figure 7 Driver Uninstall Location The USBXpress installation files are located with the ClockBuilder Desktop Software The driver files for the EVB may be reinstalled from this location or b...

Страница 9: ...J1 SMA CLK0 J1 SMA CLK0 R17 2 15K R17 2 15K R20 1K R20 1K R16 2 15K R16 2 15K R4 0 R4 0 U1 Si5356 U1 Si5356 EPAD 25 CLK4 14 I2C_LSB 3 OEB 6 CLKIN 4 SSC_DIS 5 XB 2 XA 1 CLK3 17 CLK2 18 CLK1 21 CLK0 22 VDD 24 VDDOA 20 VDDOB 16 VDDOC 15 VDDOD 11 VDD 7 INTR 8 SCL 12 SDA 19 GND 23 CLK7 9 CLK6 10 CLK5 13 J5 SMA CLK3 J5 SMA CLK3 R23 0 R23 0 R2 0 R2 0 J7 HEADER 2x3 J7 HEADER 2x3 1 3 2 4 5 6 J10 SMA CLK7 J...

Страница 10: ... 0 1uF C10 0 1uF C18 0 1uF C18 0 1uF R44 220 R44 220 S1 SW PUSHBUTTON S1 SW PUSHBUTTON R43 220 R43 220 R29 2K R29 2K C20 1uF C20 1uF R30 2K R30 2K R41 1K R41 1K C15 1uF C15 1uF D3 MMBD3004S 7 F D3 MMBD3004S 7 F R28 1K R28 1K U5 C8051F340 U5 C8051F340 VDD 10 REGIN 11 GND 7 VBUS 12 D 8 D 9 P0 0 6 P0 1 5 P0 2 4 P0 3 3 P0 4 2 P0 5 1 P0 6 48 P0 7 47 P1 0 46 P1 1 45 P1 2 44 P1 3 43 P1 4 42 P1 5 41 P1 6 ...

Страница 11: ...NC O2 17 SDO O1 16 VLOGIC 10 CSB AD0 13 RESB AD1 14 SHDN_B 15 VDD 7 DIS 9 SDI SDA 11 CLK SCL 12 VSS 18 C39 1uF C39 1uF TP13 GND RED TP13 GND RED C25 10uF C25 10uF U15 MAX8869 U15 MAX8869 GND 10 IN 4 OUT 12 RSTB 6 SET 11 SHDNB 7 IN 5 IN 3 IN 2 OUT 13 OUT 14 OUT 15 SS 8 NC 16 NC 9 NC 1 EPAD 17 C22 1uF C22 1uF R49 10 R49 10 C33 10uF C33 10uF C49 1uF C49 1uF TP12 GND RED TP12 GND RED R55 10K R55 10K U...

Страница 12: ...met B45196H5106M309 5 17 C22 C23 C24 C26 C28 C29 C31 C32 C34 C35 C36 C39 C44 C45 C47 C49 C52 1 µF 10 V 10 C0603 Venkel C0603X7R100 105K 6 6 C37 C38 C41 C42 C50 C53 0 01 µF 10 V 20 C0402 Venkel C0402X7R100 103M 7 1 D1 RED LED S GW KA Panasonic LN1271RAL 8 2 D2 D3 MMBD3004S 7 F 300 V SOT23 AKC Diodes Inc MMBD3004S 7 F 9 2 D4 D5 GREEN LED S GW AK Panasonic LN1371G 10 8 J1 J2 J3 J5 J6 J8 J9 J10 SMA SM...

Страница 13: ...5 R2512 Venkel CR2512 2W 10R0D 27 4 R52 R53 R55 R56 10 k 5 R0402 Venkel CR0402 16W 103J 28 1 R57 47 5 k 1 R0603 Venkel CR0603 10W 4752F 29 1 R58 15 4 k 1 R0603 Venkel CR0603 10W 1542F 30 1 S1 SW PUSHBUTTON 12 Vdc SW PB MOM Mountain Switch 101 0161 EV 31 1 TP4 Black TESTPOINT Kobiconn 151 203 RC 32 1 U1 Si5356 3 3 V QFN24N4X4P0 5 Skyworks Si5356 A A GM 33 1 U2 25 MHz XTAL4N3 2X2 5 FA238 Epson FA 23...

Страница 14: ...SPC Technology 2397 41 4 Richco NSS 4 4 01 42 10 Jumpers Sullins SPC02SYAN 43 1 C21 10 µF 25 V 20 6032_EIAC Kemet B45196H5106M309 44 1 J4 SMA SMA EDGE 5 Johnson Components 142 0701 801 45 1 R7 0 R0402 Venkel CR0402 16W 000 46 13 TP1 TP2 TP3 TP5 TP6 TP7 TP8 TP9 TP10 TP11 TP12 TP13 TP14 RED TESTPOINT Kobiconn 151 207 RC Table 2 Si5356 EVB Bill of Materials Continued Item Qty Reference Value Voltage ...

Страница 15: ... and Product Information are Subject to Change Without Notice November 5 2021 DOCUMENT CHANGE LIST Revision 0 1 to Revision 0 2 Changed Any Rate Clock Generator to ClockBuilder Desktop throughout Changed MultiSynth Clock Programmer to ClockBuilder Desktop throughout Updated Figure 3 on page 5 Removed Uninstaller Option figure Updated Figure 8 on page 8 ...

Страница 16: ...RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Skyworks products are not intended for use in medical lifesaving or life sustaining applications or other equipment in which the failure of the Skyworks products could lead to personal injury death physical or environmental damage Skyworks customers using or selling Skyworks products for use in such applications do so at the...

Отзывы: