3.13 LED
The terminal has a red LED to indicate that the terminal has successfully powered on or
powered off (Section 4.9).
The standard flash rates for the IDP-800 are listed in Table 23.
Table 23
LED Flash Rates
Flash Reason
Flash Rate
On Time
Period
Number of
Cycles
Total Time
Pass-Through
Mode
Slow
200 milli-
seconds
2 seconds
5
10 seconds
Terminal
Power On
Normal
200 milli-
seconds
1 second
10
10 seconds
Error
Detected
Fast
50 milli-
seconds
250 milli-
seconds
40
10 seconds
Terminal
Already
Powered On
Normal
200 milli-
seconds
1 second
5
5 seconds
Entering
Power Off
Fast
50 milli-
seconds
250 milli-
seconds
20
5 seconds
The LED can be optionally controlled by the Lua Framework. Refer to [T204] for further